11.5 Replacing the miniature fuse

If the miniature fuse is defective
(T8AL/250V), then it can be replaced with the
spare fuse supplied.
There is a spare miniature fuse in the fuse
holder
unit is delivered.
- Press the power switch
flash unit so that it is in position (Off).
- Remove the power plug from the power
socket.
k
- Use a small screwdriver to push the fuse
holder
amount.
- Then, pull out the fuse holder
with your hand.
- Take the defective miniature fuse out of the
holder and put it to the side.
- Take the new miniature fuse out of the
reserve holder and plug it into the centre of
the holder.
- Carefully push the fuse holder
compartment as far as it will go.
94
Allow the studio flash unit to cool after
use.
To exclude overloading the studio flash
unit, the technical values of the new
miniature fuse must coincide with those
of the defective miniature fuse.
DANGER OF FIRE AND ELECTRIC SHOCK
of the studio flash unit when the
vof the studio
out of its compartment by a small
completely

12 Troubleshooting

If at some time, the studio flash unit no longer works as it should,
for example there is a nonsensical display in the Touchscreen
the studio flash unit, then switch off the studio flash unit for approx.
10 seconds with the power switch
now operate "normally" when switched on. If this is not the case,
then please contact your dealer.
Here are some problems that may occur
while the studio flash unit is being used with possible causes
and/or remedies:
The studio flash unit is switched on, but none of the displays of the
unit are illuminated
• The power cord is not plugged in correctly or not plugged in at all:
Plug in the power cord correctly.
• The miniature fuse is defective:
Replace the defective miniature fuse with a new one.
The displays of the studio flash unit illuminate, but it is not
possible to trigger a flash
• The capacitor of the studio flash unit may be defective:
Please contact your dealer.
The modelling lamp flickers
• The bulb of the modelling lamp is defective:
Replace the defective bulb with a new one.