9 TECHNICAL SPECIFICATIONS

Volumetric
fl ow rate
Model
[m³/min]
HRD 1T FU-105/0,75
2,7
HRD 1T FU-105/1,1
11,0
HRD 14T FU-105/1,5
12,0
HRD 14T FU-105/2,2
24,0
HRD 16T FU-105/1,5
7,0
HRD 16T FU-105/2,2
20,0
HRD 16T FU-105/3,0
35,0
HRD 2T FU-95/2,2
13,5
HRD 2T FU-95/3,0
27,0
HRD 60 FU-105/4,0
14,0
HRD 60 FU-105/5,5
25,0
HRD 60 FU-105/7,5
39,5
HRD 65 FU-100/4,0
12,0
HRD 65 FU-100/5,5
27,0
HRD 65 FU-100/7,5
62,0
HRD 7 FU-105/11,0
27,0
HRD 7 FU-105/15,0
38,0
HRD 7 FU-105/20,0
97,0
*1)
Value at n max. respectively limiting point
Operating and assembly instructions HRD FU-ATEX
Total
Motor
pressure
Voltage
speed
differential
[Pa]
[min
]
[V]
-1
4900
5949
400
4900
6200
400
4900
5940
400
4900
6040
400
6100
5940
400
6100
6040
400
6100
5928
400
8500
5466
400
8500
5364
400
10500
6105
400
10500
6090
400
10500
6069
400
9000
6000
400
9000
5930
400
9000
5910
400
16000
6110
400
16000
6240
400
16000
6180
400
Power con-
Motor
Frequency
sumption
output
[Hz]
[A]
[kW]
105
1,9
0,75
105
3,4
1,10
105
4,1
1,50
105
4,7
2,20
105
4,1
1,50
105
4,7
2,20
105
8,0
3,00
95
4,55
2,20
95
7,3
3,00
105
11,5
4,00
105
11,2
5,50
105
15,7
7,50
100
10,5
4,00
100
12,0
5,50
100
16,0
7,50
105
24,2
11,00
105
36,0
14,00
105
38,9
20,00
Sound
EN
Weight
pressure
level L
*1)
A
[kg]
[db A]
26,0
83
42,0
83
35,0
83
43,0
86
39,0
98
45,0
96
48,0
93
55,0
87
62,0
87
61,0
93
78,0
93
110,0
91
69,0
98
83,0
98
115,0
97
130,0
98
154,0
98
225,0
97
21