Herunterladen Inhalt Inhalt Diese Seite drucken

Declaration Of Installation Conformity Pursuant To Annex Ii 1 B; Technical Specifications; D-73760 Ostfildern; Speeds - Elektror HRD 7 FU 120 Betriebs- Und Montageanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Operating and assembly instructions HRD 7 FU 120

8 DECLARATION OF INSTALLATION CONFORMITY PURSUANT TO ANNEX II 1 B

DECLARATION OF CONFORMITY IN ACC. WITH EVPG (ENERGY CONSUMPTION
RELEVANT PRODUCTS ACT).SECTION 4 PARAGRAPH 1
EN
The manufacturer,
Elektror airsystems gmbh
Hellmuth-Hirth-Strasse 2
D-73760 Ostfi ldern
hereby declares that the product to which this declaration refers meets the basic requirements of the Machinery Directive (2006/42/
EC) as set forth below.
Description of incomplete machine:
High Pressure Blower HRD 7 FU-120/22
Serial number and year of manufacture can be found on the nameplate and on the accompanying delivery slip.
Description of the essential requirements of Machinery Directive (2006/42/EC), with which the partially completed
machine complies:
Machinery Directive (2006/42/EC): Annex I, Articles 1.1.2, 1.1.3, 1.1.5, 1.3.2, 1.3.3, 1.3.4, 1.3.7, 1.5.1, 1.6.1, 1.7.1, 1.7.
Electromagnetic Compatibility Directive (2014/30/EU)
Eco-design Directive for Energy-related Products (2009/125/EC)
The partially completed machine described here continues to fulfi l the protective regulations of the Low Voltage Directive
(2014/35/EC) according to Annex I, No. 1.5.1 of the Machinery Directive.
The commissioning of the partially completed machine is not permitted until it has been verifi ed that the machine in which the partially
completed machine is to be installed, complies with the provisions of the Machinery Directive (2006/42/EC).
The following harmonised standards have been applied:
DIN EN ISO 12100 2011
DIN EN 60034-1
DIN EN 60034-5
DIN EN 60204-1
DIN EN 60664-1
As manufacturer, Elektror airsystems gmbh undertakes to forward the special technical documentation in respect of the partially
16
completed machine to national authorities at their request. The special technical documentation in respect of this partially completed
machine according to Appendix VII Part B has been created.
The person responsible for the documentation is Mr Kevin Kargar, Tel. +49 711 31973-1179.
Kreher (Managing Director)
Ostfi ldern, 17.01.2020

9 TECHNICAL SPECIFICATIONS

Volumetric
fl ow rate
Type
[m³/min]
HRD 7 FU
-120/22
Min. value / max. value of characteristic curve
*1)
Safety of machinery - General principles of design -
Risk assessment and risk reduction
2011
Rotating electrical machines,
Part 1: Rating and performance
2007
Rotating electrical machines,
Part 5: Degrees of protection provided by the integral
design of rotating electrical machines (IP code) – Classifi cation
2019
Safety of machinery – Electrical equipment of machines,
Part 1: General requirements
2008
Insulation coordination for equipment within low-voltage systems,
Part 1: Principles, requirements and tests
Max.
Total
permitted
pressure
blower
diff erence
speed
[Pa]
[min
]
-1
45,0
18.500
7.200
Motor
Voltage
Frequency
speed
[min
]
[V]
[Hz]
-1
see motor
see motor
operating
operating
7.200
instruc-
instruc-
tions
tions
www.elektror.com
Power
Motor
consump-
Weight
power
tion
[A]
[kW]
[kg]
see motor
see motor
operating
operating
137
instruc-
instruc-
tions
tions
Sound
pressure
level
min/max
*1)
[db A]
101/106