E411
Filter change required
E412
Level sensor carbonator defective
E413
Check water supply
E500
Malfunction hot water
All red LEDs are on
E501
Malfunction hygienisation power failure
All red LEDs are on
E502
Malfunction water in the device
All red LEDs are on
E503
Malfunction water in the base
All red LEDs are on
E504
Malfunction buttons
All red LEDs are on
E505
Malfunction hygienisation sensor hot
All red LEDs are on
E506
Malfunction hygienisation sensor cold
All red LEDs are on
E507
Malfunction hygienisation sensor ambient
All red LEDs are on
E508
Malfunction temperature heating module too high
All red LEDs are on
E509
Malfunction hot sensor
All red LEDs are on
E510
Malfunction ambient sensor
All red LEDs are on
E511
Malfunction cold sensor 1
All red LEDs are on
E512
Malfunction cold sensor 2
All red LEDs are on
E513
Malfunction cooling 1 defective
All red LEDs are on
E514
Malfunction cooling 2 defective
All red LEDs are on
E515
Malfunction cooling 1
All red LEDs are on
E516
Malfunction cooling 2
All red LEDs are on
E600
Malfunction electronics
All red LEDs are on
E601
Malfunction electronics
All red LEDs are on
E602
Malfunction electronics
All red LEDs are on
E603
Malfunction electronics
All red LEDs are on
E604
Malfunction electronics
All red LEDs are on
E610
Invalid device code
30
Exceeding a maximum run time (device
run time) for the various filters (1 year).
Level sensor CO
mixer defective.
2
No or insufficient water inflow.
Heating module defective.
Hygienisation was not successful
Water leakage inside the device.
Leakage inside the base.
Buttons defective.
Hygienisation was not successful
Hygienisation was not successful
Hygienisation was not successful
Heating module.
Sensor hot water defective.
Sensor unchilled water defective.
Sensor cooling module 1 defective.
Sensor cooling module 2 defective.
Cooling module 1 defective
Cooling module 2 defective
Temperature cooling module 1 too low.
Temperature cooling module 2 too low.
Malfunction unit control on the control
panel.
Malfunction unit control of the display.
Malfunction unit control base board.
The temperature of the unit control is too
high.
Malfunction unit control of the brightness
sensor.
The setting of the device code is incorrect Inform service.
13
-
EN
Change the filter.
E400: Replace Active-Pure filter
E401: Replace Hy-Protect filter
E402: Replace Hy-Pure filter (WPD 100)
Set the appliance switch to "0".
Set the appliance switch to "I".
If it is occurs again, contact service.
Clean the inlet sieve in the water connection (see "Care and mainte-
nance/cleaning inlet sieve").
Check water connection.
Set the appliance switch to "0".
Set the appliance switch to "I".
If it is occurs again, contact service.
Set the appliance switch to "0".
Inform service.
Start the hygienisation again.
Set the appliance switch to "0".
Inform service.
Set the appliance switch to "0".
Switch the machine back on again.
If it is occurs again, contact service.
Start the hygienisation again.
If it is occurs again, contact service.
Set the appliance switch to "0".
Restart the device after approx. 10 minutes.
If it is occurs again, contact service.
Set the appliance switch to "0".
Inform service.
Set the appliance switch to "0".
Restart the device after approx. 5 minutes.
If it is occurs again, contact service.