Herunterladen Inhalt Inhalt Diese Seite drucken

Kärcher WPD 100 Advanced Originalbetriebsanleitung Seite 27

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Replacing the CO
2
1
Rotating regulator
2
Pressure reducer
3
Union joint
4
Main tap
5
Pressure gauge control pressure
6
CO
hose
2
With WPD 200 and 600 the button for carbonated water
(sparkling) is inactive and "CO
Empty" is blinking when
2
the CO
bottle must be replaced.
2
With WPD100 there is no indication.
 Set the appliance switch to "0".
 Open the door on the support leg.
 Close the gas bottle at the main tap.
 Turn the pressure regulator to 0.
 Unscrew the pressure reducer from the empty gas
bottle.
 Screw the protective cap onto the empty gas bottle.
 Loosen the tie down strap for securing the CO
 Remove the empty gas bottle.
 Insert the new gas bottle in the base and secure it
by means of the tie down strap.
 Unscrew the protective cap from the new gas bottle.
 Briefly open the main tap so that possibly present,
liquid CO
can escape.
2
 Screw the pressure reducer onto the new gas bot-
tle. Watch for correct mounting of the sealing ring!
 Slowly open the main tap on the gas bottle.
 Set 3 bar on the pressure reducer by means of the
control knob.
 Close the main tap on the gas bottle.
 Read the value indicated on the pressure gauge
control pressure.
 The indicated value must remain constant for at
least 5 minutes.
 With detectable pressure reduction:
Check if the O-ring between the gas cylinder and
the pressure reducer is present and free of dam-
age. Replace defective O-ring.
Check the correct positioning of the pressure re-
ducer.
Tighten covering nut firmly.
Check the hose coupling on the pressure reducer
and the CO
hose for visible damage. In case of
2
doubt, call the Customer Service.
 If the pressure reduction cannot be remedied by
the stated measures, the pressure reducer is de-
fective and must be replaced.
 Open main tap.
 Set the operating pressure on the pressure reducer
by means of the control knob.
WPD 100: Presetting 4 bar, re-adjustable if neces-
sary.
WPD 200/600: Set the CO
pressure regulator to
2
approx. 3 bar (static) prior to the dispensing of
water and then check if the pressure is approx.
3.0 bar during the dispensing of carbonated water
(sparkling).
 Close the door of the base.
 Set the appliance switch to "1".
 Place an receptacle underneath the water outlet.
bottle
 After renewing the CO
"sparkling water" so that the CO2 mixer fills up
again.
Note:
WPD 100 Lower CO
WPD 200
WPD 600
Note:
If the pressure reducer is separated from the CO
although there is still sufficient pressure, the O-ring be-
tween the bottle and the pressure reducer is deformed
and must be replaced.
Replacing the 425 g CO
bottle.
2
1
Pressure regulator
2
Screw connection of the bottle
3
425 g CO
 Remove drip pan and open the device door.
 Turn the pressure regulator to "OFF".
 Unscrew the 425 g CO
connection in the clockwise direction.
 Remove the 425 g CO
 Remove the cover of the new CO
 Screw the 425 g CO
connection of the pressure regulator.
 If a resistance can be noticed, turn the 425 g CO
bottle slightly further until it is tightened. A short
hissing noise may be audible.
 Pre-set the pressure regulator to "4".
 Close device door and insert drip pan.
 After initial startup, readjust the pressure on the
pressure regulator in order to achieve the desired
CO
concentration in the water.
2
Note:
Water stream splashes
strongly
Lower CO
Note:
425 g CO
2
ics stores and supermarkets.
bottle, dispense one litre of
2
Water stream splash-
Water mildly carbon-
es strongly
ated
pressure Increase CO
2
sure
Check CO
pressure.
2
Adjust compensation regulator (see "User
menu/operating parameters/user settings/
portioning").
bottle
2
bottle
2
bottle from the bottle screw
2
bottle.
2
bottle.
2
bottle onto the bottle screw
2
Water mildly carbonated
pressure
Increase CO
pressure
2
2
bottles are available in drug stores, electron-
10
-
EN
pres-
2
bottle
2
2
27

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Wpd 600 advancedWpd 200 advanced

Inhaltsverzeichnis