10.2. Compressed air outlet
(Fig.7)
At the compressed air outlet (1) of the compressor, connect
the pressure hose. Connect the hose to the appliance.

10.3. Electrical connection

Plug the electrical cord into the mains.
The appliance is equipped with a grounded plug. Make sure this connection complies
with local electrical codes. The mains voltage and frequency must comply with the data
stated on the appliance label.
(Fig.8)
 Keep the socket easily accessible to ensure that in an emergency the
appliance can be safely disconnected from the mains.
 Connection to the power distribution box must be max.16 A.
 The connection of the earth ground pin  6mm (1) with other
appliances must be completed in accordance with local electrical
codes. The female socket (2), which is not included in the standard
set, is an optional accessory.
Electrical cable may not contact the hot parts of a compressor. Insulation could be
damaged!
If any electrical cord or air hose is damaged it must be replaced immediately.
11.

WIRING DIAGRAMS

1/N/PE ~ 230V 50/60Hz
ELECTRIC OBJECT 1ST CAT.
S10
P10
B10
PE
X2
1
N 2 3 PE
CABINET S50 4VR
NP-DK50 4VR50-12_10-2018
40°C
PE
E10
E11
E12
E13
- 16 -
Fig.7
Fig.8
B10
Cabinet temperature switch
S10
Switch
E10, E11,E12,E13
Cabinet fan
P10
LED-SERVIS for NDM
X2
Cabinet connector
DK50 4VR/50