FLUE CONNECTION or DUCT: duct or connection element between the unit and flue for evacuation of fumes.
DUCT
technical requirements: - it must not cross rooms in which the installation of combustion units is not allowed;
- flexible metal or fibre cement pipes are prohibited;
- the use of counter-sloping elements is prohibited;
- horizontal sections must have an upward slope of at least 3%;
- the length of the horizontal section must be minimal and not more than 3 m;
- there must not be more than 3 changes of direction, without a T union;
- with change of direction > 90° a max. of 2 bends can be used with length in horizontal projection not exceeding 2 m.
- the fume duct must have a constant section and allow the recovery of soot.
CHIMNEY CAP: a device placed on the top of the flue to facilitate the dispersion of fumes into the atmosphere.
CHIMNEY CAP technical requirements:
- it must have a section equivalent to that of the flue;
- it must have a useful section not less than double the internal section of the flue;
- it must prevent the entry of rain and foreign bodies and ensure the discharge of fumes in any
atmospheric condition;
- it must ensure an adequate dilution of fumes and be positioned outside the backflow area;
- it must be without mechanical means of suction.
The direct discharge of fumes must take place on the roof and not towards closed spaces (even open
air).
2.5 Brazier and baffle position check
Before lighting the insert make sure the brazier is in the correct position, i.e. fitted in the special slots. Also make
sure the top smoke baffle is properly fitted. A wrongly positioned baffle can result in malfunctioning and excessive
blackening of the glass.
At every lighting, check the correct position of the brazier on the brazier holder.

2.6 Electrical connection

Connect the power cable to a wall outlet for easy access, otherwise, install a wall switch to allow easy electrical
disconnection for all the necessary insert operations: periodic maintenance, resetting the safety devices, etc.
The voltage supplied by the system must match that specified on the stove data plate and in the technical data
section of this manual.
During insert idle periods it is advisable to unplug the power cable.
- Make sure the electrical system is equipped with a ground and differential switch
in accordance with the current Regulations.
- Position the power cable without it touching the hot parts of the insert.
- Do not pull, detach or twist the electric cables from the insert.
45