4.2.2
Work phase
After the startup phase, the insert goes to WORK mode, which is normal operation.
Pressing the button P1 of the radiocomando the power can be planned by the value min of 1 to a value max of 5;
pressing the button instead P2 the Set of the temperature of the water can be planned (40 - 80°C) ;
pressing in continue the button P2 and P5 the Set of the temperature environment can be planned by a value min
of 7 °C to a maximum value of 40 °C.
- Make sure to check the pellet level in the hopper so that the flame does not go out due to lack of fuel.
- Make sure the unit is off when loading pellets.
- The pellet hopper cover must always remain closed, to be opened only during fuel loading.
- The bags of pellets must be kept at least 1.5 m from the insert.
If the STANDBY mode is not activated and the set temperature is reached, or if the fume temperature has reached
the set maximum value, the LCD display shows the message MODULATE or MODULATE F and the stove activates
the flame modulation procedure without any intervention by the user.
If, on the other hand, STANDBY mode is activated, the stove activates the modulation mode for a few minutes
when the SET temperature is reached. If the temperature remains above the set value, the stove shuts down.
Restart occurs after the room temperature falls below the set value by a few degrees (default 2°C).
If the temperature increases again, above a set limit, the HOT FUMES alarm appears and the insert activates the
shutdown procedure.
During normal operation, the BRAZIER CLEANING mode is activated for several seconds at fixed intervals.
4.2.3
Shutdown
To shut down the stove , just press button P3 for about 3 seconds. The auger is immediately stopped and the fume
exhaust fan goes to high speed, with the message FINAL CLEANING appearing on the display. The fume exhaust
will remain on until the insert temperature has fallen sufficiently.
At the end of the operation the message OFF will appear on the display.
During the shutdown phase the stove cannot be restarted until the fume temperature has dropped below a fixed
value for a given time. If the on button is pressed the message AWAITING COOL will be displayed.
4.2.4
Additional remote control functions
The display on the remote control shows all the information on stove operation. The basic functions are:
STATUS
OFF
START
PELLET LOADING
AWAITING FLAME
FLAME PRESENT
WORK
MODULATE– MODULATE F
BRAZIER CLEANING
FINAL CLEANING
STANDBY
AWAITING COOL-
The remote control has a keylock function. This is available only if enabled by the specialized technician during the
first installation. From the main menu, press buttons P5 and P3 in rapid succession, to activate or deactivate the
keylock function. The two messages shown opposite appear on the display.
Press button P5 to access the list of submenus. They allow the electronic controller settings to be changed. The
various submenus can be scrolled by pressing buttons P1 and P2, and can be accessed by pressing button P5 and
exited by pressing P3.
MENU 01 – Adjust fans
Non available function.
MENU 02 – Set clock
Before operating the stove , the current time and date must be set in order to have a reference for possible chrono
programming.The electronic control has a 3-volt lithium battery model CR2032 that gives the internal clock an
operation autonomy; battery replacement is necessary if the clock does not keep the time with the stove not
powered, or a series of zeros appears at restart: call an authorized service center.
To set the clock, access the menu by pressing STOVE and set the day with buttons P1 and P2. Press P7 again to
set the hours, minutes, day, month and year.
Stove off
The initial ignition start phase is in progress
Pellet loading in progress during the ignition phase
This is the phase prior to the flame appearing.
The flame has appeared and the stove is in the heating phase
Normal work phase
Power reduced because temp. reached or high fume temp.
Automatic cleaning at regular intervals
Final stove cleaning, before shutdown
Stove off for temperature reached and awaiting request
The stove cannot be relit because awaiting cooling