The use of pellets with characteristics different from those tested by the technician during first lighting involves a
new setting of the insert pellet loading parameters; this operation is not covered by the warranty.
- Store the pellets in a dry place.
- For regular and efficient operation, pellets or other fuels cannot be manually loaded
in the brazier.
- Do not load the hopper with non-conforming fuels, foreign bodies such as containers,
boxes, bags, metals etc.
- The use of poor quality and non-conforming pellets damages and compromises insert
operation, invalidating the warranty and relieving the manufacturer of any liability.

1.6 Accessories supplied

The supply includes:
Installation, use and maintenance manual;
Fire door opening - closing key;
Radio remote control.

1.7 Reference standards

Standard UNI 10683:2012: Installation requirements for heat generators burning wood or other solid biofuels;
Standard UNI EN14785:2006: Requirements for design, manufacture, construction, safety and performance,
Standard CEI EN 60335-1: Safety of electrical appliances for domestic and similar use - part 1;
Standard CEI EN 60335-2-102: Safety of electrical appliances for domestic and similar use - part 2;
Standard CEI EN 55014-1
Standard CEI EN 55014-2: Electromagnetic resistance - Requirements for electrical appliances, electric tools and
Standard CEI EN 61000-3-2: Limits for harmonic current emissions (Input current
Standard CEI EN 61000-3-3: Limitation of voltage fluctuations and flicker in low voltage supply systems for
Standard CEI EN 62233: Measuring methods for electromagnetic fields of electrical household appliances and
Standards DIN plus 51731 – UNI EN ISO 17225-2 – Ö-Norm M 7135: Standards regarding the specifications and

1.8 Data plate

The data plate is located on the inside of the pellet hopper door or on the back of the stove. It gives all the stove's
characteristic data, including the manufacturer's details, serial number, CE marking, test laboratory and the
Declaration of Performance reference number.
1.9 Decommissioning
When definitively deciding to not to use the stove any more, we recommend to disconnect the power supply and to
empty the pallet tank completely. In order to eliminate the stove, it is necessary to packaged it with a strong
packaging and then take contact with local organisation which follows the selling off operations respecting the local
rules. Otherwise we recommend to back the stove directly to the distributor when buying a similar new one.
The picture of the bin crossed is labelled on the equipment, and it means that when the device is out of
use it has to be kept separated by other wastes.

1.10 Instructions for requesting assistance and replacement parts

To request any assistance and/or replacement parts contact your dealer, area importer or the nearest authorized
service center, clearly specifying the following: product model, serial number, date of purchase, list of replacement
parts, details of faults or malfunctioning.
- All operations on components must be carried out by authorized and/or qualified personnel.
- Make sure all electrical connections are disconnected and that the insert is cold before carrying out
any work it.
- Only use original replacement parts.
instructions and marking, together with the relevant test methods for approval of
pellet-burning units ;
:
Electromagnetic resistance - Requirements for electrical appliances, electric tools and
similar electric equipment - Part 1: Interference;
similar electric equipment - Part 2: Immunity; Product family standard;
equipment with nominal current
similar with reference to human exposure.
16 A;
classification of pellets.
40
16 A per phase);
TERMOFIRE L

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis