TRANSPORT AND INSTALLATION

2.1 Packing, handling, shipment and transport
The insert complete with packing can be lifted using a lift truck, inserting the forks (of suitable length) in the special
spaces in the wooden pallet. Make sure the equipment used for lifting and carrying can take the weight specified on
the data plate and in this manual.
Avoid taking the load in areas where it could be a danger if dropped.
After opening the packaging, remove the insert and very carefully place it on a work surface, avoiding any impact,
then place it the required area, following the instructions given in the next section.
Disposal or recycling of the packing must be carried out by the end-user in compliance with the current local
regulations.

2.2 Place of installation, positioning and fire-prevention safety

The product must be installed in a domestic environment, respecting the following conditions:
-
minimum temperature not below 0°C,
-
possibility of servicing the insert, allowing entire sliding opening-closing of the monoblock,
-
availability of an approved electrical outlet, accessible after the work is finished,
-
availability of a suitable approved flue ensuring easy connection,
-
availability of adequate external ventilation to allow the entry of combustion air and for the evacuation of any
small leaks of combustion smoke
-
availability of ventilation grilles on the fireplace to avoid any overheating of the insert.
Before proceeding with installation it is necessary to check the stability and load-bearing capacity of the support
surface according to the weight of the unit, to allow the monoblock to be pulled out safely and allow normal
maintenance and/or pellet loading operations.
Any cladding must:
- be made of non-flammable material or, if using special wood or combustible
materials, the product must be insulated from the heat and fire with adequate protection in non-combustible
material to avoid the risk of fire,
- respect the minimum safety distances,
- ensure an easily accessible technical space for periodical maintenance.
When constructing the fireplace it is necessary to respect the minimum distances between the insert and the inner
walls, to ensure proper operation and safe use of the product.
The front trims fitted around the insert must allow a minimum ventilation distance of 12-15 mm to ensure proper air
recirculation and proper operation.
Given below are examples of applications with the summary table of minimum distances to be respected:
41
Ventilation distance:
minimum 10-15 mm.
Decorative trim
available on request
TERMOFIRE L