Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Connection; Wiring Diagram - Cola TERMO-FOCUS Serie Installations-, Bedienungs- Und Wartungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Turbulator and baffle position check
2.5
Before lighting the stove make sure the brazier is in the correct position, i.e. fitted in the special slots. Also make
sure the turbulator shaker device is resting in a lower position. An incorrect position of the brazier and/or turbulators
can result in malfunctioning and excessive blackening of the glass.
At every stove lighting check the correct position of the brazier and turbulator shaker device.

Electrical connection

2.6
Connect one end of the power cable to the rear socket of the stove, and the other to the wall socket.
The voltage supplied by the system must match that specified on the stove dataplate and in the technical data
section of this manual.
During stove idle periods it is advisable to remove the power cable.
-Make sure the electrical system is equipped with an earth and differential switch in accordance with the
current Regulations.
-The power cable must never touch the stove exhaust pipe.

Wiring diagram

2.7
DHW BOILER
THERMOSTAT/FLOWSWITCH
PRESSURE
TRANSDUCER
NTC
probe
room probe
suppl.
thermostat
fume
probe
PLC additional
accessories and consol
AIR FLOW METER
IGNITER
AUGER
Fume verifier encoder
BOARD L023
FUME EXTRACTION
PUMP
FAN
49
BOARD 1055
EARTH
3 WAY
VALVE
ALT= Heating chamber safety thermostat
ALD= Low pressure gauge
ALP= Pellet compartment safety thermostat
TERMO-FOCUS M