To carry out this operation, proceed as follows:
Disconnect the stove power supply.
Press buttons P3 and P5 at the same time. The message RADIO ID 0#. will appear. With the scroll buttons
select NEW UNIT' and confirm with buttons P5.
Select the ID value with the P1 and P2 buttons from 0 to 64 (default ID = 0).
Connect the stove power supply.
Within 10 seconds after turning on the power, confirm the selected channel by pressing button P5.
The message UNIT LOADED and then stove status will appear in quick succession while the emergency
LEDs remain stationary for a short time in confirmation of acquisition.
If the message SEARCHING FIELD appears, tuning was unsuccessful and the procedure must be
repeated.
The remote controller display changes according to the status of the insert, or the menu displayed. When idle, the
display shows the following items:
Insert function
Time
During the normal operation, the data transmission happens to regular intervals of time.
To turn on the radiocomando to press the key P3 with the visualization of the state of the insert with some second of
delay.
To press the key P4 to access the menu, P5 to activate the function, P1 and P2 for the choice of the parameter.
Following the available functions are listed:
- BACK ILLUMINATION (adjustable duration from 2 to 10 sec)
- POWER ON (Time ON of the radicomando)
- BRIGHTNESS' (ON. OFF)
- CONTRASTt (Regulation contrast)
- BUZZER (I Play to the pressure of the keys of the radiocomando)
4.2.1
Lighting
Before lighting the stove:
make sure to have read and understood the instructions in the manual;
the hopper must be filled with pellets;
the combustion chamber must be clean;
the brazier must be completely free, clean of any combustion residuals and properly positioned in the
brazier holder;
check the hermetic closure of the fire door and ash pan;
make sure the stove is completely inserted in its compartment and that it is properly electrically powered.
- At first lighting, remove any components that could burn (instructions/label) from the insert firebox.
- Any lightings done after long unit idle periods require the renewal of any pellets that have been inside
the hopper for a long time (in being a damp fuel no longer suitable for combustion) and complete
cleaning of the combustion chamber.
- Do not use flammable liquids to light the unit.
- In case of persistent failed lighting, contact the Service Center.
To light the stove press button P3 on the remote control. The message START will appear on the LCD display. This
phase is automatic and is managed entirely by the electronic control, without any possibility of changing the
parameters.
The stove carries out the startup phases in sequence according to the procedure defined by the parameters. If the
fume temperature has not reached the minimum permissible value, the stove goes in alarm status. If the
temperature is reached, after a certain time, the insert goes in work status.
50
Room temperature
Water temperature
Power level