1.4 Technical description

The insert works exclusively on pellets, providing healthy and safe heat in the room. Its automatic control systems
ensure optimum heat output and complete combustion; there are also safety systems to guarantee safe operation
for the unit's parts and for the user.
When correctly installed, the unit works with any outside climatic conditions, and in any case in critical conditions
(strong wind, frost, etc.) the safety systems can intervene, shutting it down.
The inserts model TERMOFIRE L with nominal power of 23.5 kW guarantee a maximum heatable volume of 588
m3 considering a coefficient of the building's energy demand equal to 35W/m3. It can vary depending on the
insulation, type and climatic zone.
For technical data, refer to the table on page 8.
Key:
A - Power cable connection
B - Combustion air inlet
C - Water drain in overpressure (1/2" female)
D - Water supply connection
E - System return (3/4" male)
F - System delivery (3/4" male)
G - Flue pipe connection Ø80mm
L - Turbulator shaker knobs