Connecting multiple systems

Set and change 'end' systems (infrared)

STEP 1
Aim: Prepare the motor-unit to set/delete as an 'end' motor
1
2
Method: Disconnect the motor-unit from the BUS and fit
with an IR receiver, the round 24V plug must remain in
place: remove all other RJ45 plugs from the underside of
the motor-unit and place an infrared receiver in either free
port 1 or 2 (on the underside of the motor-unit).
IR
STEP 2
Aim: Enter programming mode
Method: Point the remote control at the infrared receiver
and press button P until the LED on the underside of the
motor-unit flashes alternating green/red after 20 sec. (!)
and release the button. Now press the OPEN button of a
pre-set IR channel to program the motor as an 'end' motor
( ). The LED will light up green for 2 sec.
[The 'end' motor setting is deleted by pressing the
CLOSE button; the LED will light up red for 2 sec.]
STEP 3
Aim: confirm programming
Method: If the end motor has been set (or deleted), briefly
press the P button to confirm. The LED goes out. Remove
the 24V plug and insert it again to activate the resistor.
Repeat steps 1, 2 and 3 for the other 'end' motor.
Finally, reconnect the BUS cables.