Setting curtain positions
6300
6300 only

Determining end-positions

End positions of the curtain are determined by the position of the endstops 6002. The end
positions can be changed by moving and securing the end stops to an alternative location on
the profile. Using hexagonal Allen key size No. 2.

Changing button functions for opening and closing

First remove all plugs from the motor-unit on a system already connected.
!
When not being operated the motor-unit will automatically exit the programming mode after1
minute: the LED will go out, return to step 1.
STEP 1
Aim:
Action:
STEP 2
Action:
See:
1
2
For several linked systems:
Remember that changing the "open" and "close" positions will have consequences for any
!
central control of linked systems: for example, a central "close" command will result in the
system being opened.
6002
Enter programming mode.
Keep both buttons pressed and release as soon as the LED
flashes red (after ca. 8 sec.).
Briefly press the desired button for closing the curtains.
The system will close to confirm the new setting and
the red LED underneath the motor-unit will go out.