2. 3. COMMISSIONING

1
$IWHU KDYLQJ DI¿[HG WKH UROOHU VKXWWHU WR WKH UROOHU
tube, check that when the roller shutter is in the lower
end limit position, the rigid link is correctly positioned
DQG WKDW WKH ¿UVW VODW LV YHUWLFDOO\ EHWZHHQ WKH UXQQHUV
(as per F). If necessary, adjust the number of slats
used to improve the position of the rigid link when the
roller shutter is in the lower end limit position.
1
Always refer to the manufacturer's size and weight
FKDUWV DQG ¿WWLQJ UHFRPPHQGDWLRQV IRU WKH ULJLG OLQNV
to select those suited to the roller shutter used.
Use at least 2 rigid links to attach the roller shutter to the roller tube.
Switch the power back on.
1)
Press the "Up" button at the control point:
-
If the roller shutter rises, the wiring is correct and
FRPPLVVLRQLQJ LV ¿QLVKHG
,I WKH UROOHU VKXWWHU LV ORZHUHG JR WR WKH QH[W VWHS
Switch off the power.
2)
Reverse the brown wire and the black wire connected
-
to the control point.
Switch the power back on.
3)
Press the "Up" button to check the direction of rotation.
-

2. 4. TIPS AND RECOMMENDATIONS FOR INSTALLATION

2. 4. 1. Questions concerning the ilmo 50 WT?
Problems
The roller shutter
The wiring is incorrect.
is turning in the
wrong direction.
The roller
The wiring is incorrect.
shutter is not
operational.
The drive is hot.
The control point is not
compatible.
The roller shutter
The roller shutter is encountering
stops too soon.
friction when it moves: friction
along the runners and case,
interference between the roller
tube and the drive, etc.
The drive has been installed in a
new roller shutter.
The roller shutter
The mountings used are not
does not stop
correct.
when it reaches
the lower end
limit position.
4
Images not contractually binding
Possible causes
Copyright © 2007 - 2014 Somfy SAS. All rights reserved.
F
F
1
ON
2
OFF
3
ON
Solutions
Check the wiring and modify it if
necessary.
Check the wiring and modify it if
necessary.
Wait for the motor to cool down.
Check for compatibility and replace the
control point if necessary.
Check the roller shutter installation and
correct any friction.
If the problem continues, restore the
GULYH WR LWV RULJLQDO FRQ¿JXUDWLRQ
Restore the drive to its original
FRQ¿JXUDWLRQ VHH WKH VHFWLRQ HQWLWOHG
5HVWRULQJ WKH RULJLQDO FRQ¿JXUDWLRQ 
Check that the roller shutter is
mounted to the roller tube using rigid
links.