Herunterladen Inhalt Inhalt Diese Seite drucken

IFM Electronic Ecomat 100 CR2033 Bedienungsanleitung Seite 43

Ein-/ausgangs-modul
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Index
S-Idx
Designation
1010
0
Number of
save options
1
"Save all
parameters"
1011
0
Number of
restore options
1
"reset for all
parameters"
1014
0
COB ID
Emergency
1016
0
Number of
options
Consumer
heartbeat time
1
Consumer
heartbeat time
1017
0
Producer
heartbeat time
1018
0
Number of
identity objects
1
Vendor ID
Type
Default
Description
u8, ro
0x01
Number of the "save" options
u32, rw
0x02
Automatic saving of all changed
parameters OFF/ON.
0 = AutoSave OFF
2 = AutoSave ON
u8, ro
0x01
Number of the "restore" options
u32, rw
0x01
If the string "load" is entered here,
the parameters are assigned to the
factory default values and are valid
after the next reset.
u32, rw
- EMCY is valid (Bit 31 = 0)
0x00000080
+
- EMCY is not valid (Bit 31 = 1)
Node-ID
- 11 Bit ID (Bit 29 = 0)
- ID = 0x80 + Node ID
u8, ro
0x01
Number of the monitored units
u32, rw
0x00
Heartbeat monitoring time for node n.
Monitoring of only one node is
supported.
(If nn or tttt = 0, no monitoring is
carried out)
Note:
Node monitoring with "node guarding"
or "heartbeat" is only to be used as an
alternative.
u16, rw
0x00
Time interval [ms] where the inclination
sensor generates a producer heartbeat.
u8, ro
0x01
Device identification
u32, ro
Vendor ID to CiA specification
0x0069666D
C
M
OMPACT
ODULE
CAN identifier can be changed
by the user.
0x0nntttt = monitoring time [ms]
0x0nntttt = node number
M
CR2033
ETAL
43
PAGE

Werbung

Kapitel

Inhaltsverzeichnis
loading