Herunterladen Inhalt Inhalt Diese Seite drucken

Attaching The Exhaust Air Hose; Installing The Flue Screen; Fixing The Exhaust Air Hose (Only For Exhaust Air Operation) - hanseatic SY-3503C5-E15-C44-L191-600 Gebrauchsanleitung

Wand-dunstabzugshaube
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Attaching the exhaust air
hose
The exhaust air hose (4) must be installed
if you intend to use the exhaust hood with
exhaust air operation.
(4)
1. Insert the end of the exhaust hose (4)
with the larger diameter (153 mm) into the
connection with the check valve.
2. Secure the lower end of the exhaust hose
with the cable tie (10).

Installing the flue screen

(6)
1. Screw the wall bracket for the upper flue
screen (6) into the prepared dowels using
2 round-head screws (11).
(9)
(7)
2x
(3)
2. Place the retaining plate (7) onto the low-
er flue screen (3) so that it lines up with
the chamfers on the inside. (Screws and
elongated holes should point upwards).
3. Turn two plate screws (9) from the outside
through the retaining plate (7) and the
lower flue screen (3). Tighten the screws
somewhat, but only loosely.
(10)
4. Push the upper part (2) of the flue screen
halfway into the lower part (3) of the flue
screen.
5. Place the two parts of the flue screen on
the exhaust hood. Use the recesses.
Fixing the exhaust air
hose (only for exhaust air
operation)
• Insert the exhaust air hose into the con-
nection at the wall break (hose end with
150 mm diameter)
Page GB-13
Assembly
(2)
(3)

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis