Note:
In the case of high-voltage cables with braided shielding, the black hose must be inserted
into the gland. Tighten the union nut. The earth connection of braided shielding must be
connected to the power unit's external earthing point.
See also figure 4B.
Note:
Do not allow the high voltage cables to make a loop in the MPM;
instead they must pass directly from the unions into the connections opposite.
-
Only for the MPM with remote control option (MPM-xxR): see chapter 6
if the remote high voltage on/off option is required The Ion balance
or the Biphase option must be switched on.
- Place the cover on the box.
- Secure the cover with the two screws.
5.4. Connecting the MPM power cable
(100 - 240 V AC) L
(100 - 240 V AC) N
Figure 5: MPM power cable
- Connect the power cable to the mains power point or fit a plug. See figure 5.
- Make the two earth connections, via the power cable and via the external earth wire, with the
earthing point on the MPM. Connect the external earth wire to an earthed machine part
MPM_UM_9752080610_NL_D_GB_F_V1_5
Brown
Blue
Green/Yellow