ENGLISH
ERROR MESSAGES
No cartridge/tool
Either no tool is connected with the correct
cartridge or the heating element of the cartridge
is open.
Wrong tool
The tool which is connected is not valid.
Shortcircuit
The cartridge is in shortcircuit
System stopped by overload (100ºC / 210ºF)
The
station
has
temperature and the station stops.
WARNING MESSAGES
Overload
When the temperature of the station is close to its
maximum limit, a warning appears for 2 seconds
each 8 seconds as long the station is not cooled
down. The station does not stop.
reached
a
dangerous
(85ºC /185ºF)
SLEEP FUNCTION
Tool in sleep mode
One of the Series Advanced features is that when
the tool is placed in the holder, the temperature at
the tip drops automatically to the sleep temperature
(sleep). This function is only possible because of
the quick response time which does not make the
user realise the temperature rise to reach the
selected temperature. Thanks to the sleep mode,
oxidation levels at the tip are much lower and
therefore tip life extended to 3 to 5 times under
equal conditions of use.
To indicate that the tool is in sleep-mode, the
display will show the text SLP.
TEMP.
disc. L 10 S 11
The sleep function parameters can be modified
using the station program.
In order to take full advantage of the sleep
function and as a security measure, it is
necessary to place the tool in the stand
when it is not being used.
HIBERNATION MODE
It is only a "Sleep" second what makes the station
to be in hibernation status, that is to say, the station
keeps runnning but without heating their tools.
It is an state of minimum consumption, but when it
detects that we are using a tool, it turns out
operatively again.
The timing of the hiberation mode is independent
from the sleep mode. It activates by default after
30 minutes.
The hibernation function parameters can be
modified.
8
230ºC
SLP