Herunterladen Inhalt Inhalt Diese Seite drucken

tau K126MA Installationsanleitung Seite 20

Vorschau ausblenden Andere Handbücher für K126MA:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 28
19 - 20*
2
CH RADIO
nd
21 - 22
AERIAL
23 - 24
MOTOR (M2)
25 - 26 - 27 ENCODER (M2)
28 - 29
MOTOR (M1)
30 - 31 - 32 ENCODER (M1)
24V for
MASTER-R and T-ONE8BR
1
* The outlets can be configured using the TAUPROG (see relative instructions). The standard con-
figuration is shown in the table.
** If Jumper 6 is not plugged in, energy saving mode will be activated and, at the end of each man-
ouvre, outputs 11-12, 12-13, 14-15, 16-17 and 16-18 will be switched off.
The terminal board
(MASTER18QR / MASTER-R), or in case of fault/failure of the one for motor 1 (28-32),
see wiring diagram page 2-3.
IMPORTANT:
do not power up auxiliary relays o other devices through the 18V output
R) DC output (terminals 11 – 12) to avoid malfunctions of the control unit. Use separated
power supply / transformers instead;
do not connect switching feeders or similar apparatus close to the automation that may be
a source of disturbance.
LOGIC ADJUSTMENTS
Make the logic adjustments.
Note: when any adjusting devices (trimmers or dip-switches) on the control panel are operated,
a complete manoeuvre must be carried out in order for the new settings to take effect.
TRIMMER
T.C.A.
Automatic Closing time adjustment: from about 1 to 120 seconds (see dip-switch
no. 1);
FR.
obstacle detection sensitivity adjustment.
Note: by rotating the TRIMMER FR. clockwise the sensitivity of the gearmotor
to obstacles diminishes and therefore the thrust force increases; vice-versa, by
rotating it counter-clockwise, the sensitivity of the gearmotor to obstacles
increases and therefore the thrust force diminishes.
Dip switch
AUTOMATIC
1
CLOSING
20
2
radio channel output - for control of an additional automation
nd
or for switching on lights, etc... (N.O. clean contact)
Warning: to connect other devices to the 2nd Radio Channel
(area lighting, pumps, etc.), use an additional auxiliary relay
(see note at end of paragraph).
WARNING: the default outlet is active monostable 2 sec. To
switch it to active bistable or to modify the activation time
it is necessary to use the TAUPROG hand-held programmer
(see relative instructions).
plug-in radio-receiver aerial input , for 433.92 MHz receivers
only. (21= GROUND - 22= SIGNAL)
motor (M2) supply output 18V DC max. 300 VA.
(23= POSITIVE - 24= NEGATIVE) See note below.
Not in use
motor (M1) supply output 18V DC max. 300 VA.
(28= POSITIVE - 29= NEGATIVE)
encoder supply and input (30= WHITE signal - 31= BLUE nega-
tive - 32= BROWN positive)
for motor 2 (23-24) is to be used in support of the one for motor 1
when completely open, closure is automatic after the set time on the
On
T.C.A. trimmer has past.
Off
the closing manoeuvre requires a manual command.
K126MA
(24V for MASTER-

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis