Operating Instructions
time
duration
Z0
0.5.s
Z1
.s
Z
0.3.s
Z3
3.s
Z4
.-.40.s
Z5
0.1.s
Z6
10.s
Z7
Z8
1.s
Z9
0.1.s
Z10
0.05.s
Caution
Fault elimination must only be performed by an authorised electrician.
Fault
No.reaction.when.pressing.buttons
LED.+UB/power.does.not.illuminate
No.reaction.when.pressing.buttons
LED.+UB/power.illuminates
Note
Also check for faults via LED on the circuit board of the base control and the ELS Professional Card.
Model
Power.supply
Motor.rating
Control.voltage
Control.power
Housing.dimensions
Weight
Protection.type
Ambient.temperature.range
Fused.hook-up.connection
34
Overview of control times
Description
stop.time.in.counter.command.UP.by.button.UP.or.light.barrier
Free.time.during.freeing.of.obstructions
Stop.time.during.counter.command.UP.by.safety.edge
early.warning.time
Time.for.automatic.closing.with.integrated.time.module
'reversing.time.to.support.the.safety.edge
Yard.light.On.duration
is.programmed.automatically
Waiting.time.for.safety.edge.signal.in.lower.stop.position
Blocking.detection.time
Jogging.mode.for.end.limit.setting

Troubleshooting ?

Technical Data
S55 with ELS Professional Card
3N~.30/400.V.50/60.Hz
max..1.8.kW
4.V.DC,.not.stabilised
max..15.mA
18.x.180.x.90.mm.(W.x.H.x.D)
ca..1.5.kg.(w/o.connector.cable)
IP54.,.only.for.assembly.inside
0.°C.....+50.°C
3.x.10.A
Possible cause and rectification
•. Check.supply.voltage.(terminals.L3/L2/L1/N.(NETZ)).
•. Check.fine-fuse.F1.(400.mA.T).
•. Check.
E-STOP.
button.
(EMERGENCY-STOP)).
•. Check.safety.circuit.of.drive.(crank.(chain),.drive.temper-
ature,
.
safety.limit.switch.(S1F/S2F,.yellow.cam)).
•. Check.terminals.3/6.(STOP),.9/10.(LS),.and.14/15.(slack.
rope)..If.these.terminals.are.not.occupied,.they.must.be.
bridged.
•. Check.whether.you.are.using.a.suitable.control.card.for.
the. drive.. MLS. Basic. Card/MLS. Professional. Card. for.
drive. with. mechanical. limit. switching,. ELS. Professional.
Card.for.drive.with.electronic.limit.switching(BES)
circuit).
(terminals.
1/2. .