Operating Instructions
Connection and function of the switching outputs
Switch outputs
The.door.control.S55.can.be.expanded.with.the.Module.Card..The.relay.on.this.card.has.a.switching.capacity.of.50.V./..A.
ELS Professional Card
The.relay.function.in.position.1."relay1".or.position.."relay".can.be.assigned.by.switching.the.dip.switch.on.the.Module.Card..
Function."relay.1".or."relay.".can.be.set.on.the.ELS.Professional.Card.with.the.DIP.switches.1.5,.1.6,.1.7.following.the.table:.
Switching functions of the indicator outputs
Door status
Relay.1.switches.on.at.the.top.door.end.limit.
Relay..switches.on.at.the.bottom.door.end.limit.
In.the.event.of.door.movement,.both.relays.are.off.
Traffic lights + yard light with time delay
Relay.1.switches.on.at.the.top.door.end.limit.
(traffic.light.red/green.via.changeover.contacts)..
At.the.beginning.of.each.door.movement.relay..switches.on.and.remains.on.-.at.
the.end.of.each.door.movement.it.switches.off.after.a.delay.of.10s.(time.Z6).
Traffic lights + yard light control pulse
Relay.1.switches.on.at.the.top.door.end.limit.
(traffic.light.red/green.via.changeover.contacts)..
At.the.beginning.of.each.door.movement.relay..switches.on.for.1s
(passing.contact,.pulse.to.actuate.a.time-delay.relay).
Traffic lights + yard light with time delay
Relay.1.switches.on.when.the.door.leaves.either.of.the.end.limits.and.remains.
on..
At.the.beginning.of.each.door.movement.relay..switches.on.and.remains.on.-.
10s.(time.Z6).after.the.end.of.each.door.movement.it.switches.off.after.a.delay..
If.automatic.closing.has.been.set,.the.two.relays.switch.on.as.soon.as.the.early.
warning.time.(3.s,.time.Z3).begins.
Warning light flashing + yard light pulse
Relay.1.switches.on.when.the.door.leaves.either.of.the.end.limits.and.flashes.at.
a.rate.of.1.Hz..
At.the.beginning.of.each.door.movement.relay..switches.on.for.1s
(passing.contact,.pulse.to.actuate.a.time-delay.relay).
If.automatic.closin.g.has.been.set,.the.two.relays.switch.on.as.soon.as.the.early.
warning.time.(3.s,.time.Z3).begins.
Traffic lights + yard light with time delay
Relay.1.switches.on.3.s.(early.warning.time.Z3).before.the.door.leaves.either.of.
the.end.limits.and.remains.on..
Relay..switches.on.3.s.(early.warning.time.Z3).before.beginning.each.door.move-
ment.and.remains.on.-.at.the.end.of.each.door.movement.it.switches.off.with.a.
delay.of.10s.(time.Z6)..
Warning light flashing + yard light control pulse, with early warning
Relay.1.switches.on.for.3.s.(early.warning.time.Z3).before.the.door.leaves.either.
of.the.end.limits.and.flashes.at.a.rate.of.1.Hz..
Relais..switches.on.for.3.s.(early.warning.time.Z3).before.eachdoor.movement.
for.1.s.ON.(passing.contact,.pulse.to.actuate.a.time-delay.relay).
30
DIP 1.5
DIP 1.6
OFF
OFF
ON
OFF
ON
OFF
ON
ON
ON
ON
OFF
ON
OFF
ON
DIP 1.7
OFF
OFF
ON
OFF
ON
OFF
ON

Quicklinks ausblenden: