Operating Instructions
UP Button
Pressing.the.UP.button.opens.the.door.automatically..When.the.top.end.limit.has.been.reached.or.if.a.safety.function.responds,.
the.door.stops.automatically..If.the.UP.button.is.pressed.whilst.the.door.is.closing,.the.door.stops.instantly.and.after.a.delay.
of.0.5.s.(time.Z0).it.moves.to.the.top.end.limit.

STOP Button

Pressing.the.STOP.button.while.a.door.is.opening.or.closing.stops.the.door.in.any.position.

DOWN Button

Pressing.the.DOWN.button.closes.the.door.automatically.if.a.safety.edge.is.used..If.no.safety.edge.is.connected,.only.the.
dead-man.mode.is.possible..If.the.closing.safety.edge.or.the.photoelectric.barrier.responds,.the.door.stops.(safety.edge:.
stopping.time.Z.=.0.3.s,.photoelectric.barrier:.stopping.time.Z0.=.0.5.s).and.depending.on.the.setting.(DIP.switch.1.3).moves.
to.the.top.end.limit.or.clears.an.obstacle.(clearing.time.Z1.=..s).
Checking the direction of movement
Note
To gain access to the inside of the control box, you can offset the lid with 2 screws. That way all operator
controls and indicator lamps are accessible.
The.direction.of.drive.rotation.depends.on.how.the.three.mains.phases.are.connected.to.the.control.unit;.it.has.to.be.checked.
first..To.do.this.proceed.as.follows:
•. Move.the.door.into.semi-opened.position.with.the.emergency.release.function.
•. Insert.the.CEE.plug.into.the.CEE.socket,.or.turn.on.the.isolator.switch.
•. Check.whether.the.control.unit.is.in.dead-man.mode.by.checking.whether.the.Fault.LED.is.illuminated..If.it.is.not,.press.the.
Prog.programming.button.(for.approx..3.s).until.the.flash.cycle.of.the.Pilot.LED.changes.(one.flash)..You.are.now.in.setting.
mode.(step.1).and.are.thus.operating.the.door.in.dead-man.mode.
•. Using.the.UP.and.DOWN.buttons.check.whether.the.direction.of.door.movement.agrees.with.the.buttons.pressed..Also.
observe.the.UP.and.DOWN.direction.indicator.lamps.on.the.motherboard.of.the.S55.
If.the.direction.of.movement.does.not.correspond.to.the.button.commands,.proceed.as.follows:
•. Disconnect.the.S55.control.unit.from.the.mains.
•. Change.over.two.phases.at.the.power.supply.terminals,.e.g..the.cables.at.terminals.L1.and.L3.(see.positions.of.the.termi-
nals.and.the.wiring.diagram).
•. Check.the.direction.of.movement.again.