Varyscan
DIP-switch position: DIP-switch No.2 switch 2 off, switch 3 on

3. JB-lighting 6 channel drive mode

channel 1
x-motor
channel 2
y-motor
channel 3
gobo
channel 4
colour
channel 5
dimmer/shutter
channel 6
iris/gobo rotation
DIP-switch position: DIP-switch No.2 switch 2 and 3 on
Reset on DMX: DIP-switch No.2 switch 4
If you would like to reset your Varyscan
possibility to reset your Varyscan
If switch 4 at DIP-switch No.2 is turned off, reset on DMX is not possible.
Adjustment of DMX-addresses
Depending on the optional drive mode, you have to adjust DMX-addresses as follows. The addressing works by a binary
numeral system and in 6 channel drive mode it has to follow in six steps.
®
Varyscan
Nr.
1
2
3
4
5
®
4 1200 HMI
®
from your DMX-desk, turn switch 4 on at DIP-switch No.2. Now you have the
®
, if you transmit DMX-factor 255 via gobo channel.
: DIP-switch No.1 switch 1-9

DMX address

1
7
13
19
25
Dip switch setting
31