Preparing for first-time use
Power measurement PWR
(Only in manual mode, no storage)
Connect the DUT to the test socket. In the manual mode, choose the power
measurement option and confirm your selection by pressing "Select". The
DUT should be connected to the mains voltage and in operation during test-
ing. The display will show the level of the power consumption.
Two measurement ranges are available 1 kW and 4 kW.
62
WARNING
This device is not suitable for testing or measuring mains volt-
ages.
It is only designed for measuring DC or AC voltages up to a
maximum of 200 V.
WARNING
Never carry out these measurements until the PE conductor
resistance and the insulation resistance measurements have
been successfully carried out!
The DUT is connected to the mains voltage during measure-
ments. Therefore, be careful with devices that emit heat or
have moving parts!
®