Herunterladen Inhalt Inhalt Diese Seite drucken

Switching Two Generators In Parallel; Connecting The Control Panel - Dometic TEC29 Montageanleitung

Vorschau ausblenden Andere Handbücher für TEC29:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
TEC29, TEC29LPG
➤ Disconnect the cable which links the mains input with the circuit breaker
in the electrical distribution system of the vehicle so that the connections
can be made as shown in the circuit diagram.
➤ Use a flat plug for connecting the cable to the switch.
➤ Connect A with plug-in sleeve 4 and B with plug-in sleeve 6.
➤ Connect the cable from the 230 V connection terminal of the generator to
plug-in sleeve 1 and plug-in sleeve 3.
10.9

Switching two generators in parallel

You can switch two generators of the same model in parallel with the AG 113
changeover relay (available as an accessory), see circuit diagram (fig. j,
page 12):
Item
Description
1
230 V external voltage supply
2
Vehicle electrical distribution system
3
Generator
➤ Mount the AG 113 changeover relay in a suitable position.
➤ Disconnect the cable which links the mains input with the circuit breaker
in the electrical distribution system of the vehicle so that the connections
can be made as shown in the circuit diagram.
➤ Connect the changeover relay to the control panel, by connecting
terminal 1 to R1 and terminal 3 to R3.
➤ Connect the changeover relay to the 230 V connection on the generator,
by connecting R2 and R4.
10.10

Connecting the control panel

➤ Connect the control panel to the connection box of the generator using the
extension cable provided on the plug for the control panel (for TEC29:
fig. e 3, page 9, for TEC29LPG: fig. f 4, page 9).
10.11
TEC29 only: connecting the float
➤ Connect the float from the tank to the float connection (fig. e 3, page 9).
EN
Connecting the electrical power to the generator
49