UK | 7 Radio-controlled operation (EnOcean)
Mixed systems can only be produced
i
with an RLS 45 K control and PP 45
and PPB 30 K units. Volumetric flow
compensation of an exhaust air fan
in a mixed system is not possible.
This function is switched, using an
i
optional, central on/off switch connected
to the control's 230 V input. The switch
must be released for the supply air
operation function for exhaust air units
when in service mode, parameter
230 V AC input  Commissioning
instructions.
This function can be used to undertake a
volumetric flow adjustment with PP 45 units
with exhaust air units, for example with Maico
exhaust fans ER 60 or ECA 100 ipro.
When the function is activated, all ventilation
units connected to the (Fan1/Fan2) fan inter-
face of the room air control adopt the volu-
metric flow compensation – note setting of
connected units and connected unit types!
A certain ventilation level is specified for the
registered units/unit pairs – this depends on
the number of units.
The supply air function is only ever undertak-
en by the ventilation units connected to the
room air control affected.
The volumetric flow compensation function
is not taken into account by other power
units and room air controls in the ventilation
system.
The same applies to the special intermittent
ventilation and sleep mode functions.
When intermittent ventilation/sleep mode is
activated, the supply air operation function
takes priority. The timer time for the intermit-
tent ventilation/sleep function continues to run
in the background.
If the exhaust air units integrated into the ven-
tilation system have an overrun timer, the
duration of the overrun time must be selected
in the room air control.
The overrun time can be adjusted in service
mode (0, 6 or 15 minutes). The overrun time
cannot be interrupted by pressing keys.
46
7 Radio-controlled operation
(EnOcean)
Radio-controlled operation (EnOcean) is
implemented as follows:
Purely radio-
PP 45 combi system
controlled
with wired and radio-con-
PP45 system
trolled components
DS 45 RC
+
PP 45 RC
PP 45 RC
...
PPB 30 O
● PP 45 EO extension module can only be
combined with PP 45 RC unit pairs. Other-
wise, wired operation is required.
● For range of radio components
 Chapter 12, Technical data.
● The radio mode (EnOcean) is activated by
the specialist installer. Once radio operation
has been activated, you can teach-in/delete
EnOcean radio components directly on the
ventilation unit.
● PPB 30 ventilation units cannot be radio-
controlled.
The exceptions to this are PPB 30 O/PPB
30 K units on an RLS 45 K control with
PP 45 EO extension.
All units connected to the RLS 45 K can
be controlled with an additional DS 45 RC
radio control. The unit functionality remains
unchanged.
RLS 45 K
PP 45 EO
+
+
max. 6
PP 45 RC
PP 45 K
PP 45 O
or
max. 3
/
PPB 30 K