Herunterladen Inhalt Inhalt Diese Seite drucken

Operating Keys, Displays, Leds; Operating Keys, Switches/Buttons - Maico PP 45 O Bedienungsanleitung

Pushpull lüftungssysteme
Vorschau ausblenden Andere Handbücher für PP 45 O:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

UK | 2 Operating keys, displays, LEDs

2 Operating keys, displays, LEDs

Further information in Chapter 6

2.1 Operating keys, switches/buttons

RLS 45 O / RLS 45 K / DS 45 RC
Operation with heat recovery (HR).
With LED display.
RLS 45 O/RLS 45 K: LED
PP 45 RC: LED [17] orange
Units switch between ventilation and
air extraction in a 60-second cycle.
RLS 45 O / RLS 45 K / DS 45 RC
Cross-ventilation without heat
recovery (e. g. summer operation).
With LED display.
RLS 45 O/RLS 45 K: LED
PP 45 RC: LED [17] blue
Ventilation units run with fixed direction
of air flow in ventilation or air extraction
mode.
RLS 45 K / DS 45 RC
Ventilation level 1 to 5.
Ventilation level 0 (ventilation Off) only
possible if Off function is activated.
RLS 45 O:
Ventilation level 1 to 5.
Ventilation level 0 (ventilation Off) only
possible if Off function is activated.
RLS 45 K / DS 45 RC
Intermittent ventilation with
ventilation level 5.
Intermittent ventilation can be selected
in HR or cross-ventilation mode. With
PPB 30 K units, system operation can
only be undertaken with basic setting.
To switch on, press key for 2 seconds,
the
-LED flashes slowly.
On RC units, the current operating
mode LED [17] flashes twice, 5 times.
Operating time of 30 minutes. The
ventilation unit then switches back to
the ventilation level previously used.
To cancel, press a key.
34
RLS 45 K / DS 45 RC
Sleep mode with ventilation level 0.
Sleep mode can be selected in HR or
cross-ventilation mode. With PPB 30 K
units, system operation can only be
undertaken with basic setting. To
switch on, press key for 2 seconds,
the
-LED flashes slowly.
On RC units, all 3 LEDs light up and
then go out one after another.
Operating time of 60 minutes. The
ventilation unit then switches back to
the ventilation level previously used.
Abort: Press a key.
Intermittent ventilation, sleep mode or
i
system Off can be activated on RLS 45
K controller with optional switches.
When a function is switched on, the
LED flashes slowly.
Optional button/switch for PPB30 K
exhaust air and/or intensive venti-
lation mode
If required, the PPB 30 unit can be
switched to exhaust air mode (45 m³/h
without HR) or intensive ventilation
mode (ventilation level 5 with HR)
using an optional button/switch.
The commissioning software can be
used to set parameters for how long
these functions last and for the start
delay for the switch. Once the timer
has elapsed, the ventilation unit
switches back to the previously used
ventilation level/operating mode.
For examples of dehumidification
i
strategies and splitting of the volu-
metric flows when using several
ventilation units  Table in Appendix.