5. Putting into operation

§
Position the device so that there are no obstructions to ventilation. Do not
connect the accumulator yet. Now connect the charger to the 230V a.c. mains
supply.
§
Switch the charger on.
§
When the set has been turned on, the green mains LED lights up. None of the
other LEDs light up with open connecting sockets.
§
Setting the operating elements
§
All charger settings have to be made before connecting the accumulator.
Altering the settings during charging leads to incorrect measurements or to
the premature termination of charging.
§
The left rotary switch (cell selection) is used for adjusting the number of cells
in the accumulator pack.
§
With NiCd and NiMH accumulators, the typical nominal voltage of the
individual cells is 1.2V.
Example:
An accumulator pack of 6 cells (6 x 1.2V = 7.2V nominal voltage) is to be
charged.
If only the nominal voltage of the accumulator pack is known, you obtain
the number of cells by dividing the nominal voltage by 1.2V/cell (7.2V :
1.2V/cell = 6 cells).
So please set the cell selection switch to 6 cells, please be careful to
select the right setting.
If the setting is incorrect, the device will display an error after some time,
or the accumulator will not be charged completely.
14