mains lead neutral
b) Connect service lead
The service supply lead to
conductor. Connect the
the light is also a 2 to 3-
protective-earth conductor
core cable. The light unit's
to the earth contact (
live conductor must be
7. Screw on housing
connected to the terminal
and close again.
marked L'. The service lead
8. Fit lens (set reach to
neutral conductor must be
either 8 m or 20 m max),
connected to the terminal
see 'Reach setting' section.
marked N together with the
9. Select time
Installation using corner wall mount
Functions
Once you have connected
ready to put the system into
the unit to the mains power
operation. Two setting
supply, closed the housing
controls are concealed
and fitted the lens, you are
behind the front cover
Switch-off delay
(time setting)
The chosen light ON time
can be varied continuously
from approx. 5 sec. to a
maximum of 15 min.
Turning the adjustment
screw fully anti-clockwise
selects the shortest time of
5 sec.-15. min.
approx. 5 sec., turning the
Twilight setting
(response threshold)
The chosen detector
response threshold can be
adjusted continuously from
approx. 2 lux to 2000 lux.
Turning the adjustment
screw fully anti-clockwise
selects daylight operation
2 - 2000 lux
at approx. 2000 lux. Turning
16
threshold setting
(see
'Functions' section).
10. Locate front cover
).
and fit security screw
protect cover from
unauthorised removal.
Important: Reversing the
connections may result in
damage to the unit.
and light
The corner wall mount en-
closed with the unit pro-
vides a convenient means
of in-stalling the IS 2180-5
to internal and external
corners. Use the corner
wall holder as a template
for drilling the hole. This
way, you will drill the hole
at the right angle, allowing
you to fit the wall mount
with ease.
Important: Only carry out
time and light threshold
settings with the lens fitted.
.
adjustment screw fully
clockwise the longest time
of approx. 15 min. The
shortest time setting is
recommended for setting
the detection zone and
performing the walk test.
the adjustment screw fully
clockwise selects twilight
operation at approx. 2 lux.
The adjustment screw must
be turned fully anti-clock-
wise for setting the de-
tection zone and perform-
ing the walk test in daylight.
Continuous illumination (manual override)
If a mains switch is installed
to
in the mains supply lead, the
light is capable of the follow-
ing functions in addition to
1 x OFF/ON
2 x OFF/ON
the simple ON/OFF function.
Important:
The switch should be
actuated in rapid succession
(in the 0.5–1 sec. range)
Sensor operation
1) Switch light on:
Actuate switch twice
1 x OFF and ON.
Light will stay ON for the
period selected.
2) Switch light OFF:
Actuate switch twice
1 x OFF and ON. Light
will switch OFF or go into
5 sec.–15 min.
sensor operation mode.
3) Continuous illumination
(manual override):
Actuate switch (2 x OFF
and ON) Light will be set to
continuous illumination for
4 hours (LED - under the
lens - is lit), then auto-
matically returns to sensor
operation (LED OFF).
The light can also be
switched OFF during the
4 hours
4-hour period of continuous
illumination by switching it
OFF and then ON again.
This will return the light to
sensor operation.
17