Principle
The IS 2180-5 is equipped
detected through obstacles,
with two 120° pyro sensors
such as walls or panes of
which detect the invisible
glass. Heat radiation of this
heat emitted by moving
type will, therefore, not
objects (people, animals
trigger the sensor. With a
etc.). The heat detected is
90° angle of aperture, the
electronically converted
two pyro sensors cover a
into a signal that switches
detection angle of 180°. The
on loads (e.g. a light) con-
lens can be removed and
nected to it. Heat is not
turned, thereby permitting
Reach max. 20 m
Reach max. 8 m
Direction of approach:
Direction of approach:
towards the sensor
across the detection zone

Safety warnings

Installing the sensor in-
Disconnect the power
a
a
volves work on the mains
before attempting any
power supply. It must
work on the motion
therefore be carried out
detector.
in a professional manner
The electrical connec-
a
in conformity with national
tion lead must be dead
wiring regulations and
during installation.
supply conditions.
Therefore, switch off the
power supply first and
Please note that the
a
sensor must be protect-
check that the circuit is
disconnected using a
ed by a 10 A circuit
voltage tester.
breaker. The mains
14
two max. basic reach
settings of 8 m or 20 m.
Using the wall mounts
provided with the unit, the
infrared sensor can easily
be fitted to internal and
external corners.
Important: The most
reliable way of detecting
motion is to install the unit
so that the sensor is aimed
across the direction in
which a person would walk
and by ensuring that no
obstacles (such as trees,
walls etc.) obstruct the line
of sensor vision.
supply lead must be no
greater than 10 mm in
diameter.
Only carry out time and
a
light threshold settings
with the lens fitted.
Installation/Wall mounting
Mains supply lead
Service lead
Note: The internal corner
wall mount supplied with
the unit can also be used
for wall mounting with
surface wiring. The cables
can be conveniently routed
down the surface of the
wall behind the unit and fed
through the cable entry.
Suppy cable
Surface wiring with wall mount
The site of installation
should be at least 50 cm
from a light because heat
radiated from it may trigger
the sensor unintentionally
To obtain the specified
ranges of 8/20 m, the sen-
sor should be installed at a
height of approx. 2 m.
Installation procedure:
1. Detach front cover
2. Release clip
up lower half of housing,
3. Mark drill holes, 4. Drill
the holes, insert wall plugs
(6 mm dia.), 5. Break open
cable entry for surface or
Concealed wiring
concealed wiring.
6. Feed through mains
supply and service cable
and connect to terminals.
Use sealing plugs for
surface wiring.
a) Connect mains supply
lead
The mains supply leads is
a 2 to 3-core cable:
L = phase conductor
= neutral conductor
N
Surface wiring
PE = protective-earth
conductor
If you are in any doubt, you
must identify the cables
using a voltage tester; once
you have done so, discon-
nect the power supply
again. Connect the phase
(L) and neutral conductor
(N) to the clamp-type ter-
minal. Connect the protect-
ive earth conductor to the
earth terminal ( ).
It is of course possible to
install a mains switch in
the mains supply lead for
switching the light on and
off. This is a requirement
if you wish to select the
continuous illumination
function (see Functions).
,
and flip