Function
Infrared temperature
measurement
Type K temperature probe
Ambient temperature
Humidity
Dew point
8. Operating Instructions
General information
• Protect your eyes! Never direct the laser in the face of people or animals.
Watch also for reflective surfaces!
• Please refer to the sketches on the first pages of this manual.
• After a sudden change in the ambient temperature, the Infrared
thermometer has to be adjusted. This may take up to 30 minutes. The
thermometer will only function properly if the internal temperature of the
unit and the ambient temperature are the same.
• Infrared thermometers measure the surface temperature of an object. The
device cannot measure through transparent surfaces like glass. It would
measure the temperature of the glass surface. Cover the surface using a
black adhesive tape to compensate for this. Give the adhesive tape some
time to assume the temperature of the test object and then measure the
Range
-50°C - 0°C
(-58°F - 32°F)
0°C - 800°C
(32°F - °1.472°F)
-10°C - 537°C
(14°F - 999°F)
0°C - 45°C
(32°F - 113°F)
-10 - 0°C (14 - 32°F) or
45 - 60°C (113 - 140 °F)
20% - 80%
<20% or >80%
-10°C - 50°C
(14°F - 122°)F
EN 6
Accuracy of the
value displayed
+/- 3°C (6°F)
+/- (1,5% +2°C(4°F))
+/- (1,5% +2°C(4°F))
+/- 1°C(2°F)
+/- 1,5°C(3°F)
+/-4%
+/-5%
+/-1,5°C (3°F)