Anhang 3: Herstellerspezifische GSD-Datei (Geräte-Stamm-Datei)
;Gerätespezifische Diagnose Byte 2
Unit_Diag_Bit(32) = "Zero Point Error"
Unit_Diag_Bit(33) = "Power supply failed"
Unit_Diag_Bit(34) = "Confi. not valid"
Unit_Diag_Bit(35) = "Restart"
Unit_Diag_Bit(36) = "Coldstart with default data"
Unit_Diag_Bit(37) = "Maintenance required"
Unit_Diag_Bit(38) = "Characteristics invalid"
Unit_Diag_Bit(39) = "Ident_Number violation"
;Gerätespezifische Diagnose Byte 3
Unit_Diag_Bit(40) = "Reserved"
Unit_Diag_Bit(41) = "Reserved"
Unit_Diag_Bit(42) = "Reserved"
Unit_Diag_Bit(43) = "Reserved"
Unit_Diag_Bit(44) = "Reserved"
Unit_Diag_Bit(45) = "Reserved"
Unit_Diag_Bit(46) = "Reserved"
Unit_Diag_Bit(47) = "Reserved"
;Gerätespezifische Diagnose Byte 4
Unit_Diag_Bit(48) = "Reserved"
Unit_Diag_Bit(49) = "Reserved"
Unit_Diag_Bit(50) = "Reserved"
Unit_Diag_Bit(51) = "Reserved"
Unit_Diag_Bit(52) = "Reserved"
Unit_Diag_Bit(53) = "Reserved"
Unit_Diag_Bit(54) = "Reserved"
Unit_Diag_Bit(55) = "Extention available"
;Gerätespezifische Diagnose Byte 5
Unit_Diag_Bit(56) = "KOM-Modul"
Unit_Diag_Bit(57) = "MT-Modul"
Unit_Diag_Bit(58) = "Internal CAN error"
Unit_Diag_Bit(59) = "Serial EEPROM error"
Unit_Diag_Bit(60) = "Reserved"
Unit_Diag_Bit(61) = "Reserved"
Unit_Diag_Bit(62) = "Reserved"
Unit_Diag_Bit(63) = "Reserved"
;Gerätespezifische Diagnose Byte 6
Unit_Diag_Bit(64) = "Kal-Data error"
Unit_Diag_Bit(65) = "Gastemp. error"
Unit_Diag_Bit(66) = "Heatertemp. error "
Unit_Diag_Bit(67) = "Res. temp. error"
Unit_Diag_Bit(68) = "Sensor wire error"
Unit_Diag_Bit(69) = "Max. Gastemp. error"
Unit_Diag_Bit(70) = "Reserved"
Unit_Diag_Bit(71) = "Reserved"
;Gerätespezifische Diagnose Byte 7
Unit_Diag_Bit(72) = "Totaloverflow"
Unit_Diag_Bit(73) = "Display overflow"
Unit_Diag_Bit(74) = "Reserved"
Unit_Diag_Bit(75) = "Reserved"
Unit_Diag_Bit(76) = "Reserved"
Unit_Diag_Bit(77) = "Reserved"
Unit_Diag_Bit(78) = "Reserved"
Unit_Diag_Bit(79) = "Reserved"
;Gerätespezifische Diagnose Byte 8
Unit_Diag_Bit(80) = "Reserved"
Unit_Diag_Bit(81) = "Reserved"
Unit_Diag_Bit(82) = "Reserved"
Unit_Diag_Bit(83) = "Reserved"
Unit_Diag_Bit(84) = "Reserved"
Unit_Diag_Bit(85) = "Reserved"
Unit_Diag_Bit(86) = "Reserved"
42/14-39-DE
Thermischer Masse-Durchflussmesser FMT500-IG (Sensyflow iG)
87