Herunterladen Inhalt Inhalt Diese Seite drucken

Remote-Sensor; Compact-Elektronik - ABB FMT500-IG Betriebsanleitung

Thermischer masse-durchflussmesser
Vorschau ausblenden Andere Handbücher für FMT500-IG:
Inhaltsverzeichnis

Werbung

2.4.3
1
2
3
6
7
8
9
Bild 2-4
2.4.4
1
2
3
4
5
6
7
8
9
Bild 2-5
42/14-39-DE
Thermischer Masse-Durchflussmesser FMT500-IG (Sensyflow iG)

Remote-Sensor

Automation Products GmbH
Alzenau
Germany 2007
FMT500-IG (Sensyflow iG)
O-Code : V14224-6A111111100
Typ - Nr.: xxxx
Tamb = -25...+80 °C
IS CLASS I DIV1 Group: A,B,C,D , CLASS I Zone 0 AEx ia IIC T4...T1
DIP CLASS II,III DIV1 and 2 Group: E,F,G
NI CLASS I,II,III DIV2, Group: A,B,C,D, CLASS I Zone 2 Group: IIC T4...T1
Intrinsically safe Exia CLASS I DIV1 Group: A,B,C,D Ex ia IIC T4...T1
CLASS II,III DIV1 and 2 Group: E,F,G
CLASS I DIV2, Group: A,B,C,D Ex nA II T4...T1
when connected per drawing V14224-6...12 2,V14224-6...22 2
T4/T3 Tmed. = -20...100 °C; T2 Tmed. = -20...200 °C; T1 Tmed. = -20...300 °C;
Tmax. med. = 150 °C
x = 1 HART Version SAP Option Communication 1
x = 2 Profibus Version SAP Option Communication 2
1 Gerätehersteller, Herkunftsland, Jahr der Herstellung
2 Gerätebezeichnung, Fertigungsnummer
3 Bestellcode, SAP-Auftragsnummer
6 interne Typennummer
7 Zulässige Umgebungstemperatur, Schutzart
8 Codierung gemäß FM-Zulassung
9 Codierung gemäß CSA-Zulassung
10 Gerätetyp
11 Produktdokumentation beachten
12 CE Zeichen (EG-Konformität)

Compact-Elektronik

Automation Products GmbH
Alzenau
Germany 2007
FMT500-IG (Sensyflow iG)
O-Code : V14224-6A111111100
Voltage: 110...230 V DC/AC +/-10 %, 48...62 Hz
Power: max. 20 VA
Typ - Nr.: xxxx
Tamb = -25...+50 °C
XP CLASS I DIV1 Group: B,C,D CLASS I , Zone 1 II B T4...T1
IS Circuits for CLASS I DIV1 Group: B,C,D , CLASS I Zone 0 AEx ia IIC
DIP CLASS II,III DIV1 and 2 Group: E,F,G
NI CLASS I,II,III DIV2, Group: A,B,C,D,F,G CLASS I Zone 2 Group: IIC T4..T1
CLASS I DIV1 Group: B,C,D,F,G CLASS I , Zone 1 II B T4...T1
CLASS I Zone 1 / 0 Ex d [ia] [ib] IIC T4...T1 or Ex d [ia] IIC T4...T1
CLASS II,III DIV1 and 2 Group: E,F,G
CLASS I,II,III DIV2, Group: A,B,C,D,F,G CLASS I Zone 2 Ex nA II T4...T1
when connected per drawing V14224-7...11x2, V14224-7...21x2
T4/T3 Tmed. = -20...100 °C; T2 Tmed. = -20...200 °C; T1 Tmed. = -20...300 °C;
Tmax. med. = 150 °C
x = 1 HART Version SAP Option Communication 1
x = 2 Profibus Version SAP Option Communication 2
1 Gerätehersteller, Herkunftsland, Jahr der Herstellung
2 Gerätebezeichnung, Fertigungsnummer
3 Bestellcode, SAP-Auftragsnummer
6 interne Typennummer
7 Zulässige Umgebungstemperatur, Schutzart
8 Codierung gemäß FM-Zulassung
9 Codierung gemäß CSA-Zulassung
10 Gerätetyp
11 Produktdokumentation beachten
12 CE Zeichen (EG-Konformität)
S/N: XXX5NNNN
8323455772
HW-Rev: 1.01
IP 66, NEMA 4X
x
S/N: XXX5NNNN
8323455772
HW-Rev: 1.01
IP 67, NEMA 4X
Wichtige Informationen vorab
FMT500
0102
x
FMT500
0102
10
11
12
10
11
12
13

Werbung

Inhaltsverzeichnis
loading