Gas remote switch
For turning off the gas supply
from inside the vehicle
GS 8
(part no. 57013-01)
GS 10
(part no. 57023-01)
Test hose
(part no. 50020-61200)

Technical data

measured according to
EN 12864 or under Truma test
conditions
Gas type
Liquid gas (propane / butane)
Inlet pressure p1
0.3 – 16 bar
Outlet pressure p2
30 mbar
Flow rate Qn
See printing on the gas pressure
regulation system
Gas-flow monitor's switch-off
point
27 mbar or 125 % Qn
Gas pressure regulation sys-
tem inlet
Male threads M20 x 1.5 (G.13)
Gas pressure regulation sys-
tem outlet
Cutting-ring screw fitting
8 or 10 mm
Recommended tightening
torque
3 – 5 Nm for nut M20 x 1.5 (G.13)
Declaration of conformity
The Truma SecuMotion gas pres-
sure regulation system complies
with the pressure-device direc-
tive 97/23/EC under application
of EN 12864/D and the directive
2004/78/EC Annex VIII "Safety
Requirements for LPG-Operated
Combustion Heating Devices".
Product Identification
Number
CE-0085BQ0102
DG approval number 3894
The right to effect technical
modifications is reserved!