1. Disconnect the appliance from the mains.
2. Turn off the water supply and disconnect the water inlet pipe from the water
valve.
3. Remove any water from the water inlet pipe and the valve.
4. Connect the water inlet pipe with the valve again.
5. Remove the filters. Remove any water from the drain.

7.6 Decommissioning

1. When you do not operate the appliance for a certain period of time, e.g. during
holidays/vacancies, let a programme run (empty appliance) before.
2. Disconnect the plug und turn off the water supply of the appliance.
3. Leave the door slightly ajar to protect the seals and to avoid the generation of
unpleasant odours.

8. Trouble shooting

WARNING! Disconnect the appliance from the mains before you
clean or maintain it.
POSSIBLE CAUSES
1. The fuse in the fuse box is tripped.
2. The appliance is not supplied with
energy.
3. Low water pressure.
Drain pump works permanently.
 Overflow.
1. Some noise is normal.
2. Dishes are placed improperly. Small
objects dropped out of the racks.
3. Motor hums.
ERROR
Appliance does not work at all.
Noise.
75
MEASURES
1. Check the fuse box.
2. Check that the appliance is supplied
with energy / the door is closed
properly / the plug is in the socket.
3. Check the water supply.
 The appliance identifies an overflow.
In such a case it activates the drain
pump and deactivates the circulation
pump.
1. The detergent container has opened.
2. Check the position of the dishes.
3. Appliance was not used regularly.
Even if you do not use the appliance
regularly, let it operate once a week.