6.8 Hauptmenü (main menu)
Zum Betreten des Hauptmenüs im Hauptfenster (main screen) PRG drücken.
Tasten:
UP und DOWN: Navigation durch die Untermenüs, Fenster, Werte und
Einstellungen
ENTER: Bestätigung und Speicherung der angebrachten Änderungen
ESC: Rückkehr (bei mehrmaligem Drücken: Rückkehr zum Hauptfenster)
1.
User
1. Alarm thresholds
2. System Clock
3. Enable Scheduler
4. Defi ne time zone
5. Weekly scheduler
6. Scheduled setp.
2.
1. Regulation type
Installer
2. Probes confi g.
3. Operating options
4. Drainage options
5. Water conductivity
6. Supervisor
Main probe threshold
Alarm high
Alarm high
Limit probe threshold
Alarm high
Alarm delay
System Clock
Time
Day
Month
Year
Format
Week Day
Enable Scheduler
Enable Scheduler On/Off
Variable Setpoint
Defi ne time zone
P1-1
P1-2
P2
P3
P4
Weekly scheduler
Sunday
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Scheduled setpoints
Z1
Z2
Z3
Z4
Regulation type
Select regulation
Probe or signal type main(reg.)
Limit
Meas. units.
Cyl. Sequence
Main probes confi g.
Min value
Max value
Offset
Limit probe confi g.
Min value
Max value
Offset
Option (1/2)
Select data view on main mask
Cylinder lifetime
warning
Lifetime limit
Alarm relay logic
Pulsed alarm relay
Options (2/2)
Delay before power-off at set
point
Dehum. control
Dehum. offset
Dehum. hyster.
Disable complete emptying for foam
Drainage options (1/2)
Drain if steam request drops (quick
reg.)
Power-off electrodes when draining
Drain after inactivity time
Inactivity days
Drainage options (2/2)
Dilution drain time
(standard=100)
Dilution drain freq.
(standard=100)
Additional periodic cylinder fl ush
Time interval
Water conductivity
Override conductivity
reading (0=no)
Conductivity limit
Warning
Alarm
Supervisor connect.
Identifi cation number for BMS Network
Com.speed
Protocol type
Enable On/Off from supervisor
3.
1. Confi g.restore.
Maintenance
2. System information
3. Manual procedure
4. Change cylinder
5. Alarm history
23
Confi guration
Save confi guration
Load confi guration
Normal Values
Restore default parameters
humidifi er type
System information
Bios (only reading)
Boot (only reading)
Ver. (only reading)
Language
Show language mask to unit
start-up
Manual proced. Cyl.1
Manual procedure
Power contactor
Fill valve
Drain pump
Alarm
Dehumidif.
Manual proced. Cyl.2
(only 2 cyl. versions)
Manual procedure
Power contactor
Fill valve
Drain pump
Change cylinder 1
Empty cylinder
Reset cylinder lifetime counter
Last replace (only reading)
Flush new cylinder
Change cylinder 2 (only 2 cyl.
versions)
Empty cylinder
Reset cylinder lifetime counter
Last replace (only reading)
Flush new cylinder
Alarm history
Alarm (only reading)
Time (only reading)
Date (only reading)
"UEX-PLUS" +0300040DE - rel. 1.4 - 25.09.2015