OPERATION

Operation of the fog machine is via the cable remote control provided or via DMX.

Switching on and off

1
Switch on the machine with the power switch. The switch lights up. The fog machine
will heat up for approx. 9 minutes. While the unit is warming up, fog output will not be
possible yet.
The control indicators READY (green) and POWER (red) on the remote control will
start flashing.
2
Once the warm-up process is completed, the control indicators will stop flashing and
light up continuously. The fog machine is now ready to emit fog and can be controlled
with the remote control.
3
After operation, switch off the machine with the power switch.
The output nozzle will heat up during operation. Therefore do not touch the nozzle until it has
cooled down completely!
Prior to transportation, allow the machine to cool down and completely empty the tank.
Never operate the fog machine without fog fluid. Fire hazard due to overheating! Besides, the
unit may be damaged.

Manual Fog Output

To manually activate a fog output, press the red rocker switch MANUAL on the remote
control. While this switch is kept pressed, the unit will emit the maximum amount of fog.
The manual mode will take priority over the timer mode, i.e. when the red switch is pressed,
the unit will always emit the maximum amount of fog even if the timer mode is activated.
During operation smoke emission may stop. In this case the device is heating up
again. The control indicators READY (green) and POWER (red) will start flashing.
After a short period, the machine will be ready to emit fog again. This process
guarantees an appropriate vaporization temperature and the best fog emission
possible. The temperature is regulated by a high-quality thermostat.

Timer Mode

In the timer mode, the fog machine will automatically emit fog in adjustable time intervals
of 5 to 220 seconds. The fog output time is set to 10 seconds. With the INTERVAL control,
you can activate the timer mode and adjust the intervalls between the individual fog
outputs. In timer mode, the yellow TIMER control indicator will light up.
To deactivate the timer mode, turn the INTERVAL control back to the left stop position.