The LOW FOG button controls the ultrasonic atomizer. Press the button to switch on the atomizer (button lights
up). The machine then uses water as the primary consumable and mixes it with fog fluid. This creates a fine mist
that stays on the floor for a long time without rising in the room.
Release the button to switch off the atomizer. The machine now works as a conventional vaporizer fog machine
based on fog fluid and produces a dense fog that rises in the room.
Operation is via the display and the control buttons. Alternatively, the machine can be controlled via wireless
remote control or a DMX controller. DMX control has priority over the menu settings and the remote control.

Operating buttons

Button
FUNCTION
UP
DOWN
TIMER
VOLUME
MANUAL

Menu structure

Mode
Initiation
Warm up phase
Home screen
Operation settings
DMX settings
Wireless remote
Fluid sensor
In the timer mode, the fog machine will automatically emit fog. The time intervals, duration and fog volume depend
on the corresponding menu settings. Press the TIMER button, to activate the timer mode. The display indicates
the set time interval. The unit counts down to 0 seconds and emits fog. To deactivate the timer mode, press the
TIMER button again.

OPERATING MODE SELECTION

MENU SETTINGS

Function
Selecting menu items
Setting values and options
Setting values and options
Timer mode activation
Continuous mode activation
Manual mode activation
Display
Welcome
Warming Up
Ready To Fog
Interval Set
1-200s
Duration Set
1-200s
Timer Out
1-100%
Volume Out
1-100%
DMX512 Add.
001-512
on/off
Wireless
Fluid Sensor
on/off

TIMER OPERATION

Function
This screen appears as a greeting after switching on.
The machine is warming up and not ready for use before
the required operating temperature has been reached.
The warming up phase has been completed and the device
is now ready for use.
Adjust time interval under timer mode
Adjust duration under timer mode
Adjust fog output volume under timer mode
Adjust fog output volume under continuous mode
Set DMX starting address
Activate/deactivate wireless remote control
Activate/deactivate fluid sensor