The rotating wash brush (20) is always
in low-pressure mode and cleaning
agent will thus always be added to the
water.
If you want to use the rotating wash
brush (20) without cleaning agents, the
cleaning agent tank (17) suction hose
must be placed in an empty cleaning
agent tank or leading outside.
Cleaning and

Maintenance

Pull out the power plug before eve-
ry maintenance operation. This also
includes connecting to the water
supply or trying to eliminate leaks.
There is a risk of electrocution or of
injury from moving parts.

Cleaning

Never direct the water jet
against the pressure cleaner,
nor clean the pressure clean-
er under flowing water. This
could give rise to the danger
of electric shock and damage
the pressure cleaner!
Always keep the pressure cleaner
clean. Do not use any detergents or
solvents.
Always keep the ventilation slots clean
and free.
Only clean the pressure cleaner with a
soft brush or a slightly moist cloth.
If the standard Vario nozzle (19) is
soiled or blocked, you can remove any
foreign bodies in the nozzle using the
nozzle cleaning needle (21). Push the
nozzle tip to the front to switch over to
low-pressure operation. Rotate the noz-
zle tip to move the two metal plates in
the nozzle away from each other. This
40
enables you to reach the water outlet
opening with the nozzle cleaning nee-
dle (21). Rinse the standard Vario noz-
zle with water to remove the foreign
body.
The nozzle cleaning needle (22) is
located in a slot on the housing on
the side of the bracket for the mains
cable (4) above the wheel (7).
Maintenance
The pressure cleaner is maintenance free.
Ask our service centre to car-
ry out any work that is not
described in these instruc-
tions. Use only original parts.

Storage

Drain all the water from the pressure
cleaner.
Disconnect the unit from the water sup-
ply. Press the On/Off switch (6) to turn
on the pressure cleaner for no longer
than 1 minute until no more water es-
capes from the jet gun(1) or from the
attaching parts (18/19/20). Turn off
the unit.
Store all add-ons (18/19/20) verti-
cally with the connection side facing
downwards.
Protect the pressure cleaner and its ac-
cessories from frost when they have not
been completely drained of all water.
Store the pressure cleaner and its ac-
cessories in a frost-free room.