3. Intended Use
The charger is used to charge and discharge rechargeable batteries of the type NiMH/NiCd
(1 - 15 cells), LiPo/LiIon/LiFe (1 - 6 cells) and lead acid batteries (1 - 10 cells, 2 V - 20 V).
There are 2 outputs that are independent of each other (charge/discharge channels), the opera-
tion of which takes place via a two-line lit LC display and four operating buttons each.
• Output #1:
The charge current can be set between 0.1 A and 10.0 A (depending on the cell number/
rechargeable battery voltage). The maximum charging power is 100 W.
The discharge current can be set between 0.1 A and 6.0 A (depending on the cell number/
rechargeable battery voltage). The maximum discharging power is 10 W.
• Output #2:
The charge current can be set between 0.1 A and 5.0 A (depending on the cell number/
rechargeable battery voltage). The maximum charging power is 50 W.
The discharge current can be set between 0.1 A and 2.0 A (depending on the cell number/
rechargeable battery voltage). The maximum discharging power is 5 W.
The combined total charging capacity for channels 1+2 is 100 W.
The charger also offers a connection for an external temperature sensor (not enclosed, can be
ordered as an accessory) for rechargeable-battery monitoring at each output. For multiple-cell
lithium rechargeable batteries, a balancer is integrated for each output (two matching external
XH-adapters are enclosed for rechargeable batteries with 2 - 6 cells).
The charger has an integrated mains unit to permit operation on mains voltage (100 - 240 V/AC,
50/60 Hz). The charger may, however, also be alternatively operated on a stabilised direct voltage
of 11 - 18 V/DC (e.g. via an external vehicle lead battery or a suitable mains adapter).
The safety notes and all other information in these operating instructions always have to be
observed!
Read the operating instructions carefully and attentively, and keep them for later reference. Only
pass the product on to any third parties together with the operating instructions.
Use other than that described above can lead to damage to the product and may involve ad-
ditional risks such as, for example, short circuits, fire, electrical shock etc. The entire product
must not be modified or converted, and the casing must not be opened!
This product complies with the statutory national and European requirements.