14.3 Guide for electrical installation

1. Check that the drive and motor match each other. Compare the rated voltage and rated
current of the unit.
2. If the motor must be connected to an AKD-B/P/T/M drive with 230V rated supply voltage
(AKD-xzzz06 types), then the ferrule tips supplied on motor power wires must be trimmed
by approximately 2 to 3 mm.
3. Ensure that there is proper earthing of the drive and the motor. Use correct earthing and
EMC-shielding according to the AKD installation manual. Earth the mounting plate and
motor housing.
4. The shielding must be connected to the drive (refer to the AKD installation manual).
5. Connect up all system shielding via a wide surface-area contact (low impedance) and
metallized connector housings or EMC-cable glands.
System with AKMH
and AKD-P
AKMH Installation | 14   Electrical Installation
Kollmorgen | June 2015
61