AKMH Installation | 10   Safety
Hot surface!
The surfaces of the motors can be very hot in operation, according to their protection
category. Risk of minor burns! The surface temperature can exceed 100°C. Measure the
temperature, and wait until the motor has cooled down below 40°C before touching it.
Earthing! High voltages!
It is vital that you ensure that the motor housing is safely earthed to the PE (protective earth)
busbar in the switch cabinet. Risk of electric shock. Without low-resistance earthing no
personal protection can be guaranteed and there is a risk of death from electric shock.
Not having optical displays does not guarantee an absence of voltage. Power connections
may carry voltage even if the motor is not turning.
Do not unplug any connectors during operation. There is a risk of death or severe injury from
touching exposed contacts. Power connections may be live even when the motor is not
rotating. This can cause flashovers with resulting injuries to persons and damage to the
contacts.
After disconnecting the drive from the supply voltage, wait several minutes before touching
any components which are normally live (e.g. contacts, screw connections) or opening any
connections.
The capacitors in the drive can still carry a dangerous voltage several minutes after
switching off the supply voltages. To be quite safe, measure the DC-link voltage and wait
until the voltage has fallen below 60V.
Secure hanging loads!
Built-in holding brakes do not ensure functional safety!
Hanging loads (vertical axes) require an additional, external mechanical brake to ensure
personnel safety.
Evaluate chemical compatibility of the motor cable!
Compatibility of the cable to cleaning solutions used in the application should be evaluated
before subjecting the cable to long-term exposure to chemicals. Long-term exposure of the
motor cable to chemicals not compatible with the motor cable could result in contamination
of product, motor failure, and electrocution hazard due to the exposure of high voltage wiring
inside the motor cable.
Evaluate chemical compatibility of the optional cable tube!
Silicone tubing protects the cable and electrical interfaces on these motors from exposure to
cleaning solutions and avoids emissions from the motor cable. Exposure of the silicone
tubing to strong mineral acids should be avoided to avoid chemical degradation of the
silicone tubing. Compatibility of the silicone tubing with cleaning solutions used in the
application should be evaluated before subjecting the silicone tubing to long-term exposure to
chemicals. Long-term exposure of the silicone tubing to chemicals not compatible with the
silicone tubing could result in contamination of product, motor failure, and electrocution
hazard due to the exposure of high voltage wiring inside the motor cable.