11.4.1 Frame size, flange and shaft options

Dimension drawings can be found from chapter "Dimension Drawings" (➜ # 73).
Framesize Flange
2
2
3
3
4
4
5
5
6
6
1) acc. to EN 60034-7......2) acc. to EN 42955......3) acc. to EN 50347
Mount/Shaft availability
Motor
AKMH2
AKMH3
AKMH4
AKMH5
AKMH6
Flange mounting (flange types Ax, Gx):
The basic style for flange mounting is style IM B5 according to EN 60034-7.
Mount the o-ring (FDA approved) for flange sealing.
Mounting styles IM V1, IM V3 and IM B5 with cable bushing on top are not allowed in
hygienic applications. Mount the cable bushing in the "down" part of motor to promote
drainage after washdown. Add a strain relief to the cable if necessary.
Flange
Pilot
type
diameter
diameter
A, C
79 mm
40 mm
G, H
A, C
89 mm
60 mm
G, H
A, C
114 mm
80 mm
G, H
A, C
148 mm
110 mm
G, H
132 mm
95 mm
A, C
186 mm
130 mm
G, H
AC
AN
CC
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
AKMH Installation | 11   Package
Shaft
Accuracy
Accuracy
1)
diameter
pilot
shaft
11 mm
j6
in development
14 mm
j6
in development
19 mm
j6
in development
24 mm
j6
24 mm
j6
32 mm
j6
in development
Mount/Shaft
CN
GC
GN
x
x
x
x
x
x
x
Kollmorgen | June 2015
Tolerance
2)
3)
class pilot
k6
N
k6
N
k6
N
k6
N
k6
N
k6
N
HC
HN
x
x