Herunterladen Inhalt Inhalt Diese Seite drucken

Endress+Hauser Prosonic FMU 860 Betriebsanleitung Seite 110

Vorschau ausblenden Andere Handbücher für Prosonic FMU 860:
Inhaltsverzeichnis

Werbung

Kapitel 11: PROFIBUS-DP-Schnittstelle
Transducerblock TB2
110
Parameter
Blockparameter
AI2 OUT
AI2 PV_SCALE
AI2 OUT_SCALE
AI2 LIN_TYPE
AI2 CHANNEL
AI2 PV_FTIME
AI2 ALARM_HYSTERESIS
AI2 HI_HI_LIMIT
AI2 HI_LIMIT
AI2 LO_LIMIT
AI2 LO_LO_LIMIT
AI2 HI_HI_ALM
AI2 HI_ALM
AI2 LO_ALM
AI2 LO_LO_ALM
AI2 SIMULATE
AI2 OUT_UNIT_TEXT
AI2 View1
Der Transducerblock TB2 beinhaltet diejenigen Geräteparameter, die dem Kanal 2
zugeordnet werden können.
Parameter
Standardparameter
Transducer block 2 block object
TB2 Static revision
TB2 Device tag
TB2 Strategy
TB2 Alert key
TB2 Target mode
TB2 Mode block
TB2 Alarm summary
E+H-Parameter
TB2 Measured value Channel 2
TB2 Empty calibration Channel 2
TB2 Full calibration Channel 2
TB2 Application Channel 2
TB2 Type of sensor Channel 2
TB2 Value for 0/4mA Channel 2
TB2 Value for 20mA Channel 2
TB2 Output damping Channel 2
TB2 Measured distance Channel 2
TB2 Measured level Channel 2
TB2 Linearization Channel 2
TB2 Actual level Channel 2
TB2 Input level Channel 2
TB2 Input volume Channel 2
TB2 Line number Channel 2
TB2 Diameter of vessel Channel 2
TB2 Vmax / Qmax Channel 2
TB2 Limit back water alarm Channel 2
TB2 Range for auto. suppression Channel 2
TB2 Echo attenuation Channel 2
TB2 Signal / noise ratio Channel 2
TB2 If no echo Channel 2
TB2 Safety alarm Channel 2
TB2 Envelope curve statistics Channel 2
TB2 FAC threshold Channel 2
TB2 FAC rise Channel 2
TB2 Device tag Channel 2
TB2 Unit Channel 2
TB2 Text Channel 2
TB2 View1
E+H Matrix
Slot
Index
Size
(CW II)
[bytes]
2
26
5
2
27
8
2
28
11
2
29
1
2
30
2
2
32
4
2
35
4
2
37
4
2
39
4
2
41
4
2
43
4
2
46
16
2
47
16
2
48
16
2
49
16
2
50
6
2
51
16
2
61
13
E+H Matrix
Slot
Index
Size
(CW II)
[bytes]
2
120
20
2
121
2
2
122
32
2
123
2
2
124
1
2
125
1
2
126
3
2
127
8
V4H0
2
128
4
V4H1
2
129
4
V4H2
2
130
4
V4H3
2
131
1
V4H4
2
132
1
V4H5
2
133
4
V4H6
2
134
4
V4H7
2
135
4
V4H8
2
136
4
V4H9
2
137
4
V5H0
2
138
1
V5H1
2
139
4
V5H3
2
140
4
V5H4
2
141
4
V5H5
2
142
1
V5H6
2
143
4
V5H7
2
144
4
V5H8
2
145
1
V6H0
2
146
4
V6H1
2
147
2
V6H2
2
148
1
V6H3
2
149
1
V6H4
2
150
1
V6H5
2
151
1
V6H6
2
152
1
V6H7
2
153
1
VAH1
2
154
16
VAH5
2
155
1
VAH9
2
156
1
2
157
13
Prosonic FMU 860...862
Type
Read
Write
Storage
Class
DS33*
x
D
floating point(2)
x
x
S
DS36*
x
x
S
unsigned8
x
x
S
unsigned16
x
x
S
floating point
x
x
S
floating point
x
x
S
floating point
x
x
S
floating point
x
x
S
floating point
x
x
S
floating point
x
x
S
DS39*
x
D
DS39*
x
D
DS39*
x
D
DS39*
x
D
DS50*
x
x
S
Octet String(16)
x
x
S
OSTRING
x
D
Type
Read
Write
Storage
Class
DS32*
x
C
unsigned16
x
N
Octet String(32)
x
x
S
unsigned16
x
x
S
unsigned8
x
x
S
unsigned8
x
x
S
DS37*
x
D
DS42*
x
D
floating point
x
D
floating point
x
x
S
floating point
x
x
S
unsigned8
x
x
S
unsigned8
x
x
S
floating point
x
x
S
floating point
x
x
S
floating point
x
x
S
floating point
x
D
floating point
x
D
unsigned8
x
x
S
floating point
x
x
S
floating point
x
x
D
floating point
x
x
D
unsigned8
x
x
D
floating point
x
x
S
floating point
x
x
S
unsigned8
x
x
S
floating point
x
x
S
integer16
x
D
unsigned8
x
D
unsigned8
x
x
S
unsigned8
x
x
S
unsigned8
x
x
S
unsigned8
x
x
S
unsigned8
x
x
S
Octet String(16)
x
x
S
unsigned8
x
x
S
unsigned8
x
x
S
OSTRING
x
D
Endress+Hauser

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Prosonic fmu 862

Inhaltsverzeichnis