Kapitel 11: PROFIBUS-DP-Schnittstelle
Gerätemanagement
Analog Input Block AI1
108
Parameter
E+H-Parameter
TBAux Relay selection
TBAux Relay funktion
TBAux Switch-on point
TBAux Switch-off point
TBAux Alternating pump control
TBAux Count factor C1
TBAux Count factor C2
TBAux Count factor C3
TBAux Internal time
TBAux Switch delay
TBAux Operating mode
TBAux Select current
TBAux 4 mA threshold
TBAux Select distance unit
TBAux Flow unit
TBAux Counter unit
TBAux Limit switch
TBAux External temperatur sensor
TBAux Internal counter high
TBAux Internal counter low
TBAux Reset counter
TBAux Simulation level
TBAux Simulation volume
TBAux Simulation current
TBAux View1
Parameter
Directory objekt header
Composite list directory entries
Der Analog Input Block AI1 enthält den Messwert des ersten Kanals und ist mit dem
Transducerblock TB1 verbunden. Er enthält folgende Parameter:
Parameter
Standardparameter
Analog input block 1 block objekt
AI1 Static revision
AI1 Device tag
AI1 Strategy
AI1 Alert key
AI1 Target Mode
AI1 Mode block
AI1 Alarm summary
Blockparameter
AI1 OUT
AI1 PV_SCALE
AI1 OUT_SCALE
AI1 LIN_TYPE
AI1 CHANNEL
AI1 PV_FTIME
AI1 ALARM_HYSTERESIS
AI1 HI_HI_LIMIT
AI1 HI_LIMIT
AI1 LO_LIMIT
AI1 LO_LO_LIMIT
AI1 HI_HI_ALM
AI1 HI_ALM
AI1 LO_ALM
AI1 LO_LO_ALM
AI1 SIMULATE
AI1 OUT_UNIT_TEXT
AI1 View1
E+H Matrix
Slot
Index
Size
(CW II)
[bytes]
V1H0
0
128
1
V1H1
0
129
1
V1H2
0
130
4
V1H3
0
131
4
V1H4
0
132
1
V1H5
0
133
4
V1H6
0
134
4
V1H7
0
135
4
V1H8
0
136
2
V1H9
0
137
1
V8H0
0
138
1
V8H1
0
139
1
V8H2
0
140
1
V8H3
0
141
1
V8H4
0
142
1
V8H5
0
143
1
V8H6
0
144
1
V8H7
0
145
1
V8H8
0
146
2
V8H9
0
147
2
V9H4
0
148
2
V9H7
0
149
4
V9H8
0
150
4
V9H9
0
151
4
0
152
13
E+H Matrix
Slot
Index
Size
(CW II)
[bytes]
1
0
12
1
1
24
E+H Matrix
Slot
Index
Size
(CW II)
[bytes]
1
16
20
1
17
2
1
18
32
1
19
2
1
20
1
1
21
1
1
22
3
1
23
8
1
26
5
1
27
8
1
28
11
1
29
1
1
30
2
1
32
4
1
35
4
1
37
4
1
39
4
1
41
4
1
42
4
1
46
16
1
47
16
1
48
16
1
49
16
1
50
6
1
51
16
1
61
13
Prosonic FMU 860...862
Type
Read
Write
Storage
Class
unsigned8
x
x
S
unsigned8
x
x
S
floating point
x
x
S
floating point
x
x
S
unsigned8
x
x
S
floating point
x
x
S
floating point
x
x
S
floating point
x
x
S
unsigned16
x
x
S
unsigned8
x
x
S
unsigned8
x
x
S
unsigned8
x
x
S
unsigned8
x
x
S
unsigned8
x
x
S
unsigned8
x
x
S
unsigned8
x
x
S
unsigned8
x
x
S
unsigned8
x
x
S
unsigned16
x
S
unsigned16
x
S
unsigned16
x
x
D
floating point
x
x
S
floating point
x
x
S
floating point
x
x
S
OSTRING
x
D
Type
Read
Write
Storage
Class
OSTRING
x
C
OSTRING
x
C
Type
Read
Write
Storage
Class
DS32*
x
C
unsigned16
x
N
Octet String(32)
x
x
S
unsigned16
x
x
S
unsigned8
x
x
S
unsigned8
x
x
S
DS37*
x
D
DS42*
x
D
DS33*
x
D
floating point(2)
x
x
S
DS36*
x
x
S
unsigned8
x
x
S
unsigned16
x
x
S
floating point
x
x
S
floating point
x
x
S
floating point
x
x
S
floating point
x
x
S
floating point
x
x
S
floating point
x
x
S
DS39*
x
D
DS39*
x
D
DS39*
x
D
DS39*
x
D
DS50*
x
x
S
Octet String(16)
x
x
S
OSTRING
x
D
Endress+Hauser

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Prosonic fmu 862

Inhaltsverzeichnis