Herunterladen Inhalt Inhalt Diese Seite drucken

Mounting Detergent Reservoirs; Hard-Water Treatment; Preparations For Commissioning - Kärcher HD 600 C Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
English
AUTHORISED PROFESSIONAL PERSONNEL ONLY
To keep pressure losses in the high-pres-
sure lines as low as possible, the following
recommendations should be used as man-
datory guidelines:
Flow rate
Pipeline
600 l/h
DN 15 (½")
1000 l/h
DN 15 (½")
1400 l/h
DN 15 (½")
It should be understood that the above gui-
delines still require additional allowances
for the overall tubing length, the number of
directional changes and armatures.

4. Mounting detergent reservoirs

!
Danger!
Danger of being poisoned, suffering acid
burns and fire hazard as a result of impro-
per handling of detergents.
Store detergents in a place which is inac-
cessible to children. Be certain to observe
the instructions on the packaging.
The cleaning agent reservoir should be set
up in such a way that the base of the reser-
voir is not more than 2 m below the unit.

5. Hard-water Treatment

An over-high hardness of water (>15° dH)
can lead to deposits and functional faults.
Where hardness of water is relatively high,
use the Softener accessory kit.

6. Preparations for Commissioning

Thoroughly rinse entire HD system
Check entire HD system for correct
assembly and lack of leaks.
AUTHORISED PROFESSIONAL PERSONNEL ONLY
H2
H. System Installation
Hose line
DN 8
DN 8
DN 8
HD 600 / 1000 / 1400 C(H)
Only for HD xxxx CH units: Push and
secure enclosed overflow hose incl. hose
clip on hose liner at float tank. Conduct
hose end through the opening located in
the base of the plant.
Complete electrical connections in accor-
dance with the Specifications contained
in the Operating Instructions.
Check the function of decalcifying com-
ponent (if required).
Check water supply for required delivery
volume and maximum allowable tempe-
rature.
Check pump oil level. Remove threaded
plug from oil reservoir.
Before using for the first time, cut off the
tip of the cover of the oil reservoir on the
water pump.
Only for HD xxxx CH: Check direction of
rotation of the precompression pump.
Direction of rotation has to be in unison
with the arrow on the housing.
Make adjustment settings as described
in section B.4.