AUTHORISED PROFESSIONAL PERSONNEL ONLY

1. Placement

The system must be installed in dry indoor
surroundings free from explosion hazard.
The components shall be placed on firm
and level ground, and the system must be
easily accessible for the purpose of mainte-
nance procedures. The room temperature
must not exceed 40 °C.
Possible ways in which the unit can be set
up are as follows:
Mounted on the wall
Set up on the ground using the Stand
accessory kit (optional)
If wall mounting is used, the wall should be
tested for its load-bearing capability. The
supplied mounting materials are suitable for
walls made of concrete or solid brick with a
wall thickness from 11.5 cm. Information on
mounting on other types of wall construction
can be gained from "Planning manual HD-
ST".
(For drill-hole layout see specifications table).
If the unit is set up using the Stand acces-
sory kit, the procedure is described in the
supplied assembly instructions.
!
Danger!
Risk of injury from the water jet or parts
flying off.
The screw unions of all connecting hoses
and pipelines must be tight. Use only unda-
maged and manufacturer-recommended
screw unions and high-pressure hoses.

2. Connections

The water connection, the high-pressure
network and the electrical connections may
be carried out only by authorised skilled
personnel in compliance with local regulati-
AUTHORISED PROFESSIONAL PERSONNEL ONLY
5.959-490 A 12578 (12/99)
H. System Installation
ons. The water supply and the power con-
nection must be made available for conti-
nuous operation. The prescribed connected
values can be seen in the technical data.
The water quality must meet the require-
ments as specified in section "A.13 Proper
use of the equipment".
In Germany the following regulations apply:
The water supply must be equipped with a
shutoff valve, and must be connected with
the high-pressure by means of a flexible
high-pressure hose. Insufficient supply line
cross section or insufficient admission pres-
sure will result in water starvation.
In the event of excessive admission pres-
sure or the occurrence of pressure peaks in
the mains network, the installation of a
pressure regulator upstream of the system
is mandatory.
A water drain must be present at the instal-
lation site.

3. High-pressure Installation

The link between the fixed-installation pipe
network and the system must be executed
in the form of a flexible high-pressure hose
connection.
The permanent pipe network installation
must consist of as many straight runs as
possible. All high-pressure tubing must be
installed pursuant to regulations, using
vibration-dampened strain relief and fixed
pipe or tubing clamps, while allowing for
longitudinal expansion/contraction due to
the effects of temperature and pressure.
VDMA Einheitsblatt 24416 directive
"Festinstallierte Hochdruck Reinigungs-
systeme" (Fixed-installation high-pressu-
re cleaning systems)
VDE regulations
Local power-supply company regulations
English