3.2 Operating parameters

The Profibus-DP device is configured by means of the operating parameters. The values selected in the
configuration tool are stored in an EPROM or in a binary file and are transferred to the Profibus-DP slave
each time the system is started.
In the following table all parameters available are listed:
Parameters
Code Sequence
Class 2 functionality
Commissioning diagnostics
Scaling function control
Measuring units per revolution
Total measuring range (units)
Multi/Single separation
Running indication
Data_Exchange Alarm
Control bit for limit switch function
Limit switch minimum
Limit switch maximum
Data type
Parameter
octet
number
bit
bit
bit
bit
32 bits without
10 – 13
sign
32 bits without
14 – 17
sign
bit
bit
bit
bit
32 bits without
27 – 30
sign
32 bits without
31 – 34
sign